Your OP LITE AIR tent is made of 7 connected AIR beams in the main tent (and 5 beams in the annex if you choose that 
addition). The tent is inflated by the compressor that is mounted in the cabinet to the right of the door. The hose from 
the AIR compressor is threaded up through the cabinetry to the main AIR tent inlet valve. The compressor is activated 
by the button on the control panel, which also has a breaker switch should this be required.

 The air compressor is 

preset to the optimum  pressure of 6.5psi and will automatically shut off when the pressure in the AIR tent reaches 
this pressure. Occasionally you may wish to adjust the psi to account for variations in outside air pressure (caused by 
altitude, temperature and extreme wind). 

Our recommendation is to first check the suitability of the air poles at the preset 

pressure. If you then decide you require more or less pressure in the tubes the psi may be adjusted using the dial located 
on top of your compressor. Turn the dial to increase or decrease the pressure as desired, 

however you must not increase 

the pressure over 9psi and we recommend returning the pump back to 6.5 psi for normal camping.

Once your AIR tent is fully inflated and the  compressor shuts off, please remove the hose from the valve and cap the 
valve. This will stop any air leaking out around the compressor hose. Failure to remove the hose and cap the valve may 
result in tent deflation.

Each Air Beam is connected to the beams next to it by an AIR transfer hose which has an isolation valve on each end 

where it connects to the AIR beam. Each AIR transfer hose has a spring inside it to protect it from kinks and bends that 

could damage the hose or prevent air passing between the beams. We recommend regular inspection of the AIR transfer 

hoses and isolation valves to ensure they are in good condition. You can find the AIR Transfer hoses by zipping open the  

semi-circle zippers in the roof of your tent. Should you need to close off the valve, the back section is turnable. There 

are markings on the valve to show which direction to turn for open and close.

The AIR Beams are housed inside 

two protective layers; an inner thick 

protective layer and an outer layer 

built into the main tent. You should 

aim to keep the AIR beams enclosed 

inside the layers unless you suspect 

an issue with the air beam. Should 

you need to access the AIR beam, 

ensure that no part of the AIR beam 

is caught in the zip when you close it 

back up. 

 

Located on each potable water tank you will find a quick access  draining valve at the lowest point of the tank. When 
packing away the OP LITE complete the following process to drain the system of any excess water. 

A. Switch off the pump on the main control panel 
B. Open the faucet & allow the excess water in the pipe to drain 
C. Close the faucet once all of the water has drained. 
D. Disconnect either side of the quick connect 
E. Ensure the sink and waste water drain hose are empty 
F. Removing hose and stow it in the front storage panel. 

The OP LITE  is fitted with one 20gl potable water tank mounted in front of the axle. The water tank has its own lockable fill point 
located on the driver-side and identified by a blue water faucet icon. Your water tank is connected to a 12v water pump which can 
be switched on via the main control panel. The water pumps are pressure operated, so once the main power switch is turned on at 
the control panel the pump will prime the system and as soon as you turn the tap on the water will flow. Once the tap is closed, the 
pump will turn off until the tap is turned back on. Please turn off your pump at the main control panel when the water system is not 
in use as they will continue to use battery power when they are turned on but not in use. Do not run your water pump when the tanks 
are empty as this could cause the damage to the water pump and circuit. You can use the water gauges on the main control panel to 
check the water levels in your tank. 

The water tank is gravity filled and included with your OP LITE is a potable water fill hose which should be sanitized regularly. It is 
important to monitor the water levels in your tank. When your water tank is empty please turn off your water pump. Running your pump 
without water in the tank will cause your water pumps to burn out. Please see the Troubleshooting section for tips if you are not able 
to draw from your potable water tanks.

water

 

system

water

 

system

•  Use the supplied blue water hose with male quick-connect fittings on each end. 
•  Connect one side to the middle quick connect on the side of the OPUS and the 

other side to the water quick connect fitting on the kitchen, accessible when the 
kitchen is fully extended. 

•  Turn on the front pump on your control panel
•  Open the kitchen faucet.
•  The kitchen has a drain hose included in the front storage compartment.
•  This is designed to drain to a waste water container or bucket. 

      WARNING: Do not pour hot oil down the kitchen sink drain!

POtAblE 

WAtER

 

SyStEM

POtAblE 

WAtER

 

SyStEM

kItChEN SINk 

RUNNINg

 

WAtER

 

tO

 

yOUR

 

kItChEN

 

kItChEN SINk 

RUNNINg

 

WAtER

 

tO

 

yOUR

 

kItChEN

 

PACk dOWN 

WAtER

 

SyStEM

 / StOW 

yOUR

 

kItChEN

 

PACk dOWN 

WAtER

 

SyStEM

 / StOW 

yOUR

 

kItChEN

 

Summary of Contents for OP LITE

Page 1: ...1 INFO OPUSCAMPER US INFO OPUSCAMPER US O P LT V 3 2 0 2 0 2021 OWNER S MANUAL...

Page 2: ...ensure that you will still be covered under warranty Retain all invoices and documentation to allow for proper reimbursement through your dealer For appliances please refer to the appliance manual for...

Page 3: ...ll Weight 209lbs GVWR 3527lbs Coupling Lock n roll articulating hitch Suspension Independent Coil Spring Suspension with Dual Shock Absorbers Kitchen Stainless steel slide out kitchen with 4 burner st...

Page 4: ...7 6 www opuscamper us 925 215 7315 www opuscamper us 925 215 7315 OP LITE 2021 Owner s Manual OP LITE 2021 Owner s Manual dimensions...

Page 5: ...lf Ensure that you have enough slack in the chains to turn your vehicle adequately Should you require less slack the chains can be twisted or crossed below the tongue before connecting to your vehicle...

Page 6: ...highly likely all the appliances inside your camper would stop working as the batteries are not able to put out enough voltage to keep these appliances running Do not take a reading when an appliance...

Page 7: ...sure all 4 quick release valves on the AIR tent are closed and that the AIR compressor hose is in the AIR tent inlet valve As the tent is inflating pull tightly on the rear securing straps Tightly an...

Page 8: ...4 Turning on Lights Step 15 Interior Set Up Step 15 Interior Set Up Step 16 Connect Shore Power Step 16 Connect Shore Power set up guide set up guide Use your shore power extention to connect to power...

Page 9: ...ED Exterior Kitchen Light Position the flexible light to the desired position Plug the power cord for this light into the small 12v socket on the exterior of the OP LITE Ensure that the Lights switch...

Page 10: ...k Down the Interior STEP 1 Pack Down the Interior After stowing your personal items close all both layers of all windows making sure no water dirt or debris is trapped between the layers Ensure mattre...

Page 11: ...eam ensure that no part of the AIR beam is caught in the zip when you close it back up Located on each potable water tank you will find a quick access draining valve at the lowest point of the tank Wh...

Page 12: ...LITE serviced with your dealership Do not use any other gas systems than those provided with the OP LITE Always turn off the shut off valve Safely Operating your Gas System Safely Operating your Gas...

Page 13: ...itch that will control the interior footwell lights There is also a rocker switch that controls the light for the exterior light mounted to the side of the OPUS by the kitchen There is a water tank ga...

Page 14: ...y tube to help protect the hose from getting kinked Install the tube to the receiving valve in the same way as in step 2 except you will need to thread the top of the valve on to the Cross Filling Tub...

Page 15: ...ves are in the OPEN position otherwise AIR cannot pass between beams Make sure your AIR Compressor hose is securely in the AIR tent inlet valve Should you experience issues with your compressor you ca...

Page 16: ...your canvas Caring for your canvas You may also experience depending on the weather and use condensation This should not be confused with leakage To reduce the risks of condensation please ensure your...

Page 17: ...f the OP15 owner to ensure all warranty work is completed by an approved OPUS dealership Failure to do so may result in incomplete or refusal of warranty claim repair cost reimbursement Any modificati...

Page 18: ...hat this is acceptable practice I Please follow these steps for proper battery care during periods of storage if you are NOT leaving your OP4 plugged into shore power during storage 1 Completely charg...

Page 19: ...riginal date of purchase Warranties apply only to items sold as new and do not extend to any items sold via auction or deemed to be factory sec onds ex demonstration or damaged unless specifically sta...

Page 20: ...dits exchanges or similar associated with such items In the sale of such items OPUS will attempt to provide all relevant infor mation regarding the item including faults defects or similar however the...

Page 21: ...mper USA 1850 Loveridge Rd Pittsburg CA 94565 CONTACT 925 215 7315 info opuscamper us WARRANTY Register your warranty online at https www opuscamper us warranty claims ONLINE OWNER S MANUAL Download a...

Reviews: