background image

OPUS

 

   

ATX/ITX DC-DC 90W Power Supply User Guide

 

Solutions, Inc. 

 

 

 www.opussolutions.com

    

 

©

 OPUS Solutions, Inc. 2002,2003; UG-DCX3.xx09   14-MAR-04

   

 

9

 

 

 
Note: The black and Yellow wires are not required for remote / trigger use. 
 
It is intended for turning ON/OFF of the computer slave/peripheral devices.  
The slave/peripheral devices are such as LCD monitors, Amplifiers, 2 way radio, Cameras,  
Remote DVD or CR ROMs, etc. 
 
The output of the remote / trigger (Red wire) can be connected directly to the Audio Power amplifier's  
Remote or Trigger input. In this application, the computer is turned ON first, then 40 Sec later  
the amplifier will be turned on to prevent pop noise in the audio system. 
 
If slave/peripheral devices does not have trigger /Remote input, then, the Remote/Trigger output from DCX3 DC-
DC power supply can be used to power a relay, which in turn can switch the power to slave devices. 
 
 

DCX3 DC-DC PCB Dimensions 

 

Summary of Contents for DCX3.1209

Page 1: ...to shut down the PC after a delay of 20 minutes The power supply outputs are monitored to assure proper PC operation Wake up on interrupt is implemented to access the vehicle computer over wireless LA...

Page 2: ...r the this function If the PC is manually put into power down mode to restart the PC the ignition must be turned off for at least 5 sec and turned on again Abnormal condition If the green LED light fl...

Page 3: ...r cable to connect the unit to the battery Use an 18 AWG wire for ignition or on off Note Do not share power cable with other equipment s Make sure the voltage at Input power connector of the DC DC ac...

Page 4: ...eup from suspend Cntrl F1 or whatever is your preference 11 Type Esc to go back to Power Management Setup 12 Type Esc to go back to top level of BIOS setup menu 13 Select Save and Exit setup Type Ente...

Page 5: ...1 Shut down the computer Click Start Shut Down Shut Down under Shut Down Windows Note Some applications do not support standby mode In that case select Power off or hibernate in step 6 above Configuri...

Page 6: ...y for minimum time Default factory setting 4 Install the OPUS DC DC Power Supply in your computer 5 Connect the bottom end of 20 pin ATX power cable Y cable to OPUS DC DC power supply J7 ATX ITX Power...

Page 7: ...ation for Standby mode testing Use the application as you would normally 6 Turn off the computer by turning the ignition switch off The computer should go into Standby or shut down mode as it was set...

Page 8: ...ut Batt GND OPUS DCX3 DC DC LCD Monitor etc OPUS DCLxx DC DC Two Way Radio etc Audio Power Amplifier Remote Trigger output DC DC APM control Relay Not Used Not Used Fig 2 Remote Trigger output and or...

Page 9: ...ers 2 way radio Cameras Remote DVD or CR ROMs etc The output of the remote trigger Red wire can be connected directly to the Audio Power amplifier s Remote or Trigger input In this application the com...

Page 10: ...p below 10 6V 2 Flashes The computer power up sequence failed Reasons 1 Check the wiring of the two wire power switch cable from power supply connector J9 to power switch pins on the ATX motherboard I...

Page 11: ...V 6 A max 8 A pk 50mV p p max 2 5 V 6 A max 8 A pk 50mV p p max 2 12 V 2 5A max 3 A pk 50mV p p max 2 12 V 0 2 A max 4 A pk 150mV p p max 10 5 V standby 1 5 A max 2 A pk 50mV p p max 2 Power supply ef...