16
-
O80, 382 x 288 px
Distance
[m]
Field of view:
HFOV [m]
Pixel inside canthus
(15x15 mm)
Depth of field: DOF [m]
for 3x3 px
0.3
0.5
15 x 15
0.3
0.6
1.0
8 x 8
5.3
1.2
2.0
4 x 4
infinite
The following table shows the recommended installation area.
Lens
Recommended working range for
screening [m] (Distance Camera - Person)
Recommended working range for reference [m]
(Distance Camera - BR20)
min
max
min
max
O18
3
6
3
20
O29
2
4
2
18
O53
1.0
2
1
11
O80
0.6
1.2
0.6
7
The O18 or O29 optics are recommended for temperature measurement by individual screening
at the medial canthus. At least 3x3 pixels are required in the canthus area and the optimal FOV
width is 1 m.