3.Equipment installation and opening
3.1 Unpacking
Open the received cartons of the MODEL and carefully unpack its
contents. The cartons should Included following items:
Name
Quantity
EDFA
1 Set
Power Supply Cable
2pcs(DC No)
Network Cable
1pc
Serial Cable
1pc
User Manual
1pc
3.2 Installation steps
3.2.1
After the device removed, placed in a smooth horizontal table or fixed on the frame;
3.2.2
The two sets of screw nut fastening the device to the frame on both sides of the buckle ears, then bolt through the ears and ears
equipment rack, and the final rivet nut tight together;
3.2.3
Respectively the power cord connected to the Blue Line -48V (negative), the black wire to the 0V (positive), the yellow-green cable wire to
protect the ground connection.
3.2.4
The power switch to "ON" state, the indicator on the viewing panel is correct, then the Power (green) and Input Alarm (red) should be
in a light emitting state;
3.2.5
The optical port on the protective cap is removed, the input optical signal, the signal on the line if the connection is correct and, this time,
the panel only the power indicator (green) lights, other are in the off state.
4.Common Problems and Solutions
4.1
1. If no electricity after power on: please check the power supply module type you are using are the same type of power supply, and check the
power of positive and negative polarity. The power supply should comply with the specification 0f the power indicators.
2.Input alarm indicator light: Turn off the power and check the light output optical power is at the entrance of the erbium-doped optical fiber
amplifier input range. If you still can not resolve, make sure the input and output optical port device is reversed. Optical signal wavelength is within
the operating wavelength range of the device.
3.Temperature warning: Make sure that the device ambient temperature is too high
。
4.Output alarm, pump alarm: this alarm occurs, turn off the device, and contact us promptly.
4.2 Maintenance
* Do not plug the fiber jumper cables for no reason!
* Do not twist the small curvature of the fiber jumper cables!
* Please regularly maintenance, use alcohol to clean the fiber optic union, attention must first turn off the amplifier power!