![OptoSpan OTS Series User Manual Download Page 35](http://html1.mh-extra.com/html/optospan/ots-series/ots-series_user-manual_1645524035.webp)
OTS Series Command Line Interface User Guide
Page 35 of 95
3.11.5
show alarm sort-by-level {reverse}
【
Format
】
show alarm sort-by-level {reverse}
【
Description
】
This command displays all alarm information order by level.
【
Example
】
【
Display Explained in Detail
】
Parameter
Description
reverse
Display all alarm information order by level. The lowest level is on the top row.
Object
Alarm source
Description
Alarm name
Level
MJ
:
major
,
MN
:
minor
,
NA
:
no alarm, CR: critical, CL: clear
Date
Alarm detect time
192.168.0.244:> show alarm sort-by-level
Object
Level Description Date
================================================================
SH 1/1/1
Critical Loss of Signal 2015/02/12 09:48:20
LH 1/1/1-Lane1 Critical Loss of Signal 2015/02/12 09:48:22
LH 1/1/1-Lane2 Critical Loss of Signal 2015/02/12 09:48:22
LH 1/1/1-Lane3 Critical Loss of Signal 2015/02/12 09:48:22
LH 1/1/1-Lane4 Critical Loss of Signal 2015/02/12 09:48:22
LH 1/1/1-Lane5 Critical Loss of Signal 2015/02/12 09:48:22
LH 1/1/1-Lane6 Critical Loss of Signal 2015/02/12 09:48:22
LH 1/1/1-Lane7 Critical Loss of Signal 2015/02/12 09:48:22
LH 1/1/1-Lane8 Critical Loss of Signal 2015/02/12 09:48:22
LH 1/1/1-Lane9 Critical Loss of Signal 2015/02/12 09:48:22
LH 1/1/1-Lane10 Critical Loss of Signal 2015/02/12 09:48:22
Power 1/1 Major Fault 2015/02/12 09:47:42
Current Alarm Integration Status: Enable