background image

 
 

 

V 1.0 - eng 

 

23 

 

 

 

 MACHINE VISION LAB KIT 

| QUICK START GUIDE

 

5.7.  Getting an image in FabImage Studio 

1.  Open FabImage Studio. 
2.  Select Language and Filter visibility based on them complexity (Expert is Recommended). 

 

 

 

3.  Select the GenICam filter from the left panel. 

 

 

4.  Drag and Drop in the Middle panel. 

 

 

Summary of Contents for MACHINE VISION LAB KIT

Page 1: ...V 1 0 eng QUICK START GUIDE MACHINE VISION LAB KIT ...

Page 2: ...tion 10 5 4 Camera Mounting and back focal adjustment on Telecentric Lens 11 5 4 1 Assembling TC3MHR048 on CMHO048 11 5 4 2 Camera mounting and back focal adjustment 11 5 4 3 Filter mounting 12 5 5 Camera Setup 12 5 5 1 Introduction 13 5 5 2 Electrical interface 13 5 5 3 Camera installation and operation 14 5 5 4 Host network configuration 14 5 5 5 Camera network configuration 16 5 6 Lighting setu...

Page 3: ...fic manuals of the components making part of the present Product are supplied with the components and are available at www opto e com website The buyers users of the OPTO ENGINEERING Product should proceed under the own direct responsibility and at their own care and expenses with all necessary and appropriate controls test verifications and eventual operating trials in order to verify the corresp...

Page 4: ...apter as adapter overload may cause over heating or a fire hazard Please make sure that the plug is firmly connected to the power socket When the product is mounted on wall or ceiling the device shall be firmly fixed If smoke odor or noise rise from the device turn off the power at once and unplug the power cable and then please contact the service center Cautions Make sure the power supply voltag...

Page 5: ...mera focal length 12 mm EN10MPL1620 Fixed focal lens for 12MP camera focal length 16 mm EN10MPL2520 Fixed focal lens for 12MP camera focal length 25 mm EN10MPL3520 Fixed focal lens for 12MP camera focal length 35 mm EN10MPL5020 Fixed focal lens for 12MP camera focal length 50 mm TC3MHR048 C High resolution telecentric lens for 1 1 detectors magnification 0 303x C mount Lighting LTRN048YY1 Ring LED...

Page 6: ...diameter LTDVE4CH 20 Strobe controller 4 channels RT POE21U 1AF Power Over Ethernet POE Injector RT SDR 75 12 75 6W 12V 6 3A DinRail Power Supply CBETH003 Ethernet cable CAT6 industrial level high flexible cable with screw 5 m COE 6P OPEN1 030 HIROSE 6 pin Open end cable 3 meters RT 702611323 Power cord RT SDR 120 24 Power supply CBSLH 24V F 3M Illumination cable side A flying leads side B SM 3 wa...

Page 7: ...LE FI At least 1GB of hard disk space for software installation 5 2 Software installation walkthrough 5 2 1 OECS Opto Engineering Camera Studio v1 0 0 1 Download the installation archive from the following link https www opto e com products COE U series Downloads 2 Extract the archive 3 Double click on the installation executable 4 Click on Start Setup ensure to have accepted the terms of the lice...

Page 8: ...o frames 6 Wait until the installation is finished 5 2 2 FabImage Studio installation 1 Download FabImage a Visit webpage at the following link https www fab image com user_area b You must to Login in the user area if you don t have a valid account you need to create one Registration form is in the same page of the login ...

Page 9: ... Warning you need to download the full version NOT the Lite one 2 Install FabImage Studio following this guide https docs fab image com current studio getting_started Installation html Ensure to select Hardware license key runtime during installation since the Fabimage Studio license provided in this kit is hosted by a hardware dongle ...

Page 10: ...of kit camera Lenses PN Description Focal length mm FOV Angle H V D EN10MPL1220 Fixed focal lens for 12MP camera focal length 12 mm 12 49 7 40 8 55 6 EN10MPL1620 Fixed focal lens for 12MP camera focal length 16 mm 16 41 5 32 9 47 6 EN10MPL2520 Fixed focal lens for 12MP camera focal length 25 mm 25 29 5 22 5 35 0 EN10MPL3520 Fixed focal lens for 12MP camera focal length 35 mm 35 22 0 16 5 26 6 EN10...

Page 11: ...CMHO048 Please look at related video on https vimeo com 49145841 5 4 2 Camera mounting and back focal adjustment All kit lenses and camera are provided with a standard mount type C 1 32 TPI simply screw together desired lens and camera In order to obtain the best performance from a Telecentric Lens e g TC3MHR048 a back focal adjustment has to be done ...

Page 12: ...ngth by following either procedure a or b a Given M lens magnification see datasheet and d difference between the nominal working distance and the best focus distance measured on site the number of spacers that you are required to use must cover an overall thickness 𝑡 𝑀2 𝑑 If the best focus plane B F P is closer than the nominal W D then t is negative and a number of spacers must be removed wherea...

Page 13: ...for example the operating mode settings and the image parameters adjustment For further reference please read carefully the instructions manual available at the following link https www opto e com products COE U series Downloads 5 5 2 Electrical interface Description of the rear Panel No Description 1 RJ45 gigabit Ethernet interface 2 M2 screw holes for cable securing 3 6 pin power and I O interfa...

Page 14: ... desired position 3 Use one CBETH003 cable to connect the camera to a Gigabit Ethernet port of the host computer Be sure to use a network card with jumbo frames support 4 Use the COE 6P OPEN1 030 cable to connect the camera to the RT SDR 75 12 power supply 12 Vdc Please refer to the camera pinout reported in the previous section and the cable pinout 5 Connect the RT SDR 75 12 to power mains 90 264...

Page 15: ...mand on the local computer to test the network connectivity 1 Click Start Control Panel Network and Internet Network and Sharing Center Change adapter settings select the network connection and click Properties 2 Double click the TCP protocol and you can set select Obtain an IP address automatically 3 Optional You can also select Use the following IP address and set the IP address with the same su...

Page 16: ...ware or other processes are accessing the camera You need to stop the live view and disconnect the camera or terminate other processes to access the camera c If the camera status is Not Reachable the network of the camera is exceptional and you should check the camera network settings NOTE The camera status may be In Use if there is an IP address conflict with other devices Please make sure the IP...

Page 17: ...ous mode will be used For further reference please read carefully the instructions manual available at the following link https www opto e com products LTDV strobe controllers Downloads 5 6 2 Current ratings Maximum current ratings for the lighting solutions included in this bundle LTRN048YY Color Max current value Unit YY RD Red 400 mA YY GR Green 385 mA YY BL Blue 434 mA YY NW White 840 mA LT2BC...

Page 18: ...ent value Unit Y R Red 525 mA Y G Green 560 mA Y B Blue 560 mA Y W White 560 mA LTZZO130 75 3 Y 24V Color Max current value Unit Y R Red 450 mA Y G Green 570 mA Y B Blue 570 mA Y W White 570 mA Warning do not exceed current ratings during operation The products will be damaged irreversibly ...

Page 19: ...onnect an ethernet CAT5 or higher cable to a network interface on the designated PC Any network interface is compatible No driver is needed for the unit to work Configure the network interface IPv4 settings as follows Any IP address ranging from 192 168 0 1 to 192 168 0 255 excluding 192 168 0 32 is valid for the connection 5 6 4 Power up In order to safely power up the system and to reset the uni...

Page 20: ... 5 Configuration Open any web browser and digit the IP 192 168 0 32 in the address bar Press enter and wait for the interface to load On the main page some diagnostic data is available In order to setup the controller click on the Setup light outputs LD1 LD4 ...

Page 21: ...V 1 0 eng 21 MACHINE VISION LAB KIT QUICK START GUIDE This is the light output configuration page ...

Page 22: ...es can be adjusted to the need keeping in mind the limits that are reported in the current ratings section in this guide At the end of the configuration press the Apply button located at the bottom of the page If everything has been connected correctly and the configuration is good all the connected and configured light sources should light up ...

Page 23: ...TART GUIDE 5 7 Getting an image in FabImage Studio 1 Open FabImage Studio 2 Select Language and Filter visibility based on them complexity Expert is Recommended 3 Select the GenICam filter from the left panel 4 Drag and Drop in the Middle panel ...

Page 24: ...he properties of the filter just inserted and click on inAddress button 7 Select COE 123 M POE 080 IR C from Device Manager List Warning please ensure to have COE driver installed on the same computer 8 Select outFrame output from Filter and Drag and drop it in Right panel 9 Click on Start button on the Top bar ...

Page 25: ...V 1 0 eng 25 MACHINE VISION LAB KIT QUICK START GUIDE ...

Reviews: