LTDVE8CH– INSTRUCTIONS MANUAL
47
OUT_SEL_HI12
: upper nine bits of output multiplexer 13 selector (sync. output SH5)
OUT_SEL_HI13
: upper nine bits of output multiplexer 14 selector (sync. output SH6)
OUT_SEL_HI14
: upper nine bits of output multiplexer 15 selector (sync. output SH7)
OUT_SEL_HI15
: upper nine bits of output multiplexer 16 selector (sync. output SH8)
Allowed values for the selectors of the output multiplexers are listed below. Avoid operation with
non-listed values.
When 0x0000000 the output multiplexer is disabled (default value)
When 0x0000001 pulse generator 1 output is selected
When 0x0000002 pulse generator 2 output is selected
When 0x0000004 pulse generator 3 output is selected
When 0x0000008 pulse generator 4 output is selected
When 0x0000010 pulse generator 5 output is selected
When 0x0000020 pulse generator 6 output is selected
When 0x0000040 pulse generator 7 output is selected
When 0x0000080 pulse generator 8 output is selected
When 0x0000100 pulse generator 9 output is selected
When 0x0000200 pulse generator 10 output is selected
When 0x0000400 pulse generator 11 output is selected
When 0x0000800 pulse generator 12 output is selected
When 0x0001000 pulse generator 13 output is selected
When 0x0002000 pulse generator 14 output is selected
When 0x0004000 pulse generator 15 output is selected
When 0x0008000 pulse generator 16 output is selected
When 0x0010000 filtered input TR1 is selected
When 0x0020000 filtered input TR2 is selected
When 0x0040000 filtered input TR3 is selected
When 0x0080000 filtered input TR4 is selected
When 0x0100000 filtered input TR5 is selected
When 0x0200000 filtered input TR6 is selected
When 0x0400000 filtered input TR7 is selected
When 0x0800000 filtered input TR8 is selected
When 0x1000000 the output is always active (continuous)
Bit fields [15:9] of these registers are unused. When writing these bits, they must be set to zero.