background image

 

 

 

VODN46xxIR

 

 

IR  Speed  Dome 

User  Manual   

V1.0.0 

 

 

 

 

 

 

 

 

 

 

 

Distributor:

   

VOLTA Ltd 

Jutrzenki Street 94; 02-230 Warsaw 

www.volta.com.pl 

 

Summary of Contents for VODN46xxIR

Page 1: ...VODN46xxIR IR Speed Dome User Manual V1 0 0 Distributor VOLTA Ltd Jutrzenki Street 94 02 230 Warsaw www volta com pl...

Page 2: ...t notice The updates will be added into the new version of this manual We will readily improve or update the products or procedures described in the manual The content in this installation guide is on...

Page 3: ...y interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE and comply ther...

Page 4: ...e to mains AC power The socket outlet shall be installed near the equipment and shall be readily accessible Installation and Maintenance Do not connect disconnect any cables to or perform installation...

Page 5: ...equivalent in other countries has been obtained Use of this equipment in a residential location is prohibited This equipment generates uses and can radiate radio frequency energy which may result in h...

Page 6: ...uct is installed on wall or ceiling the device shall be firmly fixed 6 If smoke odors or noise rise from the device turn off the power at once and unplug the power cable and then please contact the se...

Page 7: ...e time 6 Please use the provided glove when open up the dome cover avoid direct contact with the dome cover because the acidic sweat of the fingers may erode the surface coating of the dome cover 7 Pl...

Page 8: ...tings 7 3 2 3 Configuring the PTZ Parameters 9 3 2 4 Configuring the IR Parameter Setup 11 3 2 5 Configuring the Patrol 12 3 2 6 Configuring the Pattern 14 3 2 7 Configuring the Time Tasks 15 3 2 8 Co...

Page 9: ...Support 3D Positioning function which can locate the target quickly and correctly Built in temperature sensor which can display the internal temperature of the camera Support the scheduled preset patr...

Page 10: ...e performs a series of POST power on self test which includes the lens actions and the pan and tilt movements After the power on self test finished the system information displays for 2 minutes on the...

Page 11: ...eboot 38 Patrol 4 95 Access main menu 39 IR cut filter in 96 Stop scanning 40 IR cut filter out 99 Start pan scanning 2 3 On Screen Display The IR speed dome provides a series of on screen display for...

Page 12: ...REBOOT DOME EXIT Figure 3 1 Main Menu To move the cursor and operate the menu Move the cursor up down On the IE browser live view page of the DVR click up and down direction buttons or FOCUS and FOCU...

Page 13: ...Z control panel via the IE browser of the DVR to enter the next page and return to the previous page of the submenu if more than one page is available Descriptions of system parameter configuration So...

Page 14: ...Time Setup You can set the system time See Figure 3 4 from this item according to the steps below Steps 1 Move the cursor to TIME SETUP by using the direction buttons and click IRIS to enter 2 Click...

Page 15: ...REDUCE ON HR MODE ON CONTRAST 2 SATURATION 3 BACK EXIT Figure 3 6 Camera Setup Focus Settings Steps 1 Move the cursor to FOCUS using the direction buttons and click IRIS to enter 2 Click up down direc...

Page 16: ...ilter into Black and White mode to increase the lens sensitivity in low light conditions DAY Color You can switch it to DAY mode in normal lighting conditions Note You can set the IRCUT FILTER value o...

Page 17: ...t You can set FOCUS LIMIT as 30CM 1M or 3M to make sure that the speed dome focuses on the target when you set it as 1M default the focus limit will automatically change according to the lens zooming...

Page 18: ...set PROPORTIONAL PT to ON or OFF to enable disable the function Note This function is enabled automatically while setting the patterns Park Time This feature allows the speed dome to start a predefine...

Page 19: ...levation Angle Elevation angle is used for adjusting the angle in vertical direction Note The Elevation angle function is only supported by a certain camera model series PT Check PTZ check is used for...

Page 20: ...installation which come to be the fog when the internal temperature is quite will differ from the outside temperature The heat control can warm the camera to fit the cold whether better 3 2 5 Configu...

Page 21: ...e switching between the presets 4 Follow above steps to define other presets for the selected patrol You can configure up to 32 presets in sequence for a patrol Press IRIS to save the current settings...

Page 22: ...iguration Menu Steps Move the cursor to enter the PATTERNS interface MAIN MENUS DOME SETUP PATTERN SETUP Choose the Pattern Number Steps 1 Move the cursor to PATTERN NUM and click IRIS to enter edit m...

Page 23: ...e PREVIEW menu to preview the current pattern Delete Pattern Click IRIS to enter the Delete Pattern interface and click IRIS to confirm the deletion Space Remain Space remain refers to capacity of the...

Page 24: ...mode night mode and none 3 Click IRIS again to confirm and exit the edit mode of this column 5 Set the Task Time Steps 1 Move the cursor to TASK TIME and click IRIS to enter edit mode 2 Click the left...

Page 25: ...y Mask Configuration Menu 2 Choose the Privacy Mask Number Steps 1 Move the cursor to BLANK NUM and click IRIS button to enter edit mode 2 Click the up and down direction buttons to select the number...

Page 26: ...the mask turn to gray 4 To modify the configured mask click IRIS button to enter the SET BLANK menu and click IRIS button again to modify Note The tilt range for configuring the privacy masks is from...

Page 27: ...3 2 Default Dome Settings 3 4 Restoring the Camera Settings Enter default camera settings menu MAIN MENUS RESTORE CAMERA Click IRIS to restore the camera settings to the default value or click IRIS to...

Page 28: ...trong thunderstorm area or high induction voltage areas such as high voltage transformer substation high power lightning protection apparatus and lightning conductor are necessary to be appended The d...

Page 29: ...nce theory table is shown as below Table A 1 Max Distance of RS485 Transmission Baudrate Max Distance 2400BPS 1800m 4800BPS 1200m 9600BPS 800m The transmission distance will be decreased if we use the...

Page 30: ...t satisfy the requirement of the RS485 industry standard so that it will lead to some problems such as signal reflection anti jamming ability decline when the devices are faraway At this time the spee...

Page 31: ...IR Speed Dome User Manual 23 Figure A 5 RS485 Distributor FAQ of RS485 Bus...

Page 32: ...he certain wire gauge when the 24VAC voltage loss rate is less than 10 For the AC driven device the maximum voltage loss rate allowable is 10 For example for a device with the rating power of 80VA whi...

Page 33: ...IR Speed Dome User Manual 25 Appendix 4 Table of Wire Gauge Standards American Wire Gage AWG British Standard Wire Gauge SWG Bare Wire Gauge mm Cross sectional Area of mm Bare Wire 2...

Page 34: ...ath the speed dome the speed dome will automatically rotate 90 degrees in horizontal direction to maintain continuity of tracking Auto Focus The auto focus enables the camera to focus automatically to...

Page 35: ...The speed dome can be programmed to move within the limit stops left right up down which are configurable by the control keyboard DVR or client application software Manchester Code Self test The spee...

Page 36: ...ed area will move with pan and tilt functions and automatically adjust in size as the lens zooms telephoto and wide Privacy Mask This function allows you to block or mask certain areas of a scene to p...

Page 37: ...retain color balance over a color temperature range The default setting for white balance is AUTO Wide Dynamic Range WDR When the Wide Dynamic Range WDR function is on the dome is able to balance the...

Page 38: ...First Choice for Security Professionals...

Reviews: