OPTIMUM
M A S C H I N E N - G E R M A N Y
Safety
Version 1.0.3 dated July 22, 2014
Page 12
Original operating instructions
B30 VGM
US
fatal electrocution.
The geared drill includes the following safety devices:
EMERGENCY-STOP button.
main lockable switch.
a drilling table with T-slots to hold the piece and a bench screw.
adjustable drill chuck guard with limit switch.
1.9
Safety check
Check the geared drill at least once per shift. Inform the person responsible immediately of any
damage, defect or change in operating function.
Check all safety devices
at the beginning of each shift (with the machine stopped),
once a week (with the machine in operation),
after every maintenance and repair operation.
Check the prohibition, warning and information labels and the markings on the geared drill
can be identified (if not, clean them)
are complete.
INFORMATION
Use the following overview to organize the inspections.
General check
Item
Inspection
OK
Protective covers
Fitted, firmly bolted and not damaged
Drill chuck guard
Labels, markings
Installed and legible
Date:
Inspector (signature):
Test run
Item
Inspection
OK
EMERGENCY-STOP
push button
Once the emergency stop button is activated, the geared drill
should be switched off.
Drill chuck guard
The geared drill must only be switched on, if the drill chuck
guard is closed.
Date:
Inspector (signature):