Original operating instructions
DRO 5
GB
Operation
The introductions of the main functions.
Save and Exit
Saving new parameters, press the "PROG" key to confirm, then return to the normal display state.
5.1.1 LCD display parameter setting
Contrast
Press the "PROG" key to enter the menu, selection range is 0~31, the increment or decrement is 1.
Backlight
Press the "PROG" key to enter the menu, selection range is 0~63, the increment or decrement is 1.
Test sample
Selection of three different RGB display types.
Press the "PROG" key to enter the menu, selection range is 0~3, the increment or decrement is 1.
Save and Exit
Saving new parameter, press "PROG" key to confirm, then return to the main menu.
5.1.2 Parameter setting of X Y Z-axis and speed axis
X-axis parameter
Three-level menu, press "PROG" key to enter to modify the X-axis parameter.
Y-axis parameter
Three-level menu, press "PROG" key to enter to modify the Y-axis parameter.
Z-axis parameter
Three-level menu, press "PROG" key to enter to modify the Z-axis parameter.
Speed axis parameter
Three-level menu, press "PROG" key to enter to modify the speed axis parameter.
5.1.3 Parameter setting of X-axis
Sensor
Setting of sensor type. Press "PROG" to enter the menu, there are several digital sensor types selectable.
MS100 ; MS200 ; MS500 ; CSA010 ; CSA020 ; CSA050
Use the sensor setting MS200 for reading heads in scope of delivery of DRO5.
Resolution setting
Press "PROG" key to enter and choose.
For sensor type „MS200“ , there are 4 possibilities to choose from. 2µm
ǀ
5µm
ǀ
10µm
ǀ
50µm
Use a resolution of 50 microns for the magnetic tapes with the item no. 3383978 or 3383979 or 3383980 .
Other magnetic tapes from other manufacturers, or magnetic tapes with another item number can have a
different resolution.