Optimum 3383975 Operating Manual Download Page 4

OPTIMUM

M A S C H I N E N   -   G E R M A N Y

Version 1.0.4  dated 2015-11-19

Page 18

Original operating instructions

DRO 5

GB

1.5

Basic safety information

DANGER OF EXPLOSION!

Do not use the electronic display in explosive zones.

2

Identification

The type label shows the model name with model number and serial number.

2.1

Scope of delivery

Digital Position Indicator DRO5

Magnetic plate 60 x 46mm with countersunk head screws for fixing the housing on side or bottom.

4 pcs. Plastic closing caps for threaded holes in the housing.

Speed sensor, cable length 5 meters

Connection cable power supply, cable length 6 meters

3 pcs. Magnetic sensors MS200 = MR000, without magnetic tape.

2.2

Optionally available

Magnetic tape item no. 3383978 - Length in a piece - 1100 mm , 
Resolution 0.05 mm (50

ɥ

m)

Magnetic tape item no. 3383979 - Length in a piece - 2000 mm ,
Resolution 0.05 mm (50

ɥ

m)

Magnetic tape item no. 3383980 - Bulk stock, 
Resolution 0.05 mm (50

ɥ

m)

3

Installation

3.1

Mechanical installation

CAUTION!

Failure of electronic display

When mounting pay attention to the IP type of protection.

Make absolutely sure to close not used fixing holes in the housing with enclosed plastic caps.

Avoid impact on the device.

Do not modify the device in any way.

Assembly

Fasten the device via the threaded holes (2x M5, 7 deep) onto the bottom side or onto a flat working sur-
facewith the magnet plate.
The mounting surface should be made for better grip with a suitable cleaning agent fat or oil-free.
Device dimension: height 134mm, width 98.5mm, depth 65.5mm

3.2

Electrical installation

WARNING!

Destruction of parts of equipment and loss of regulation control

Check all line connections and plug connections before switching on supply voltage.

Summary of Contents for 3383975

Page 1: ...OPTIMUM M A S C H I N E N G E R M A N Y Dreiachs Positionsanzeige Three axes position display DRO 5 Artikel Nr Item no 3383975 Version 1 0 4 Betriebsanleitung de Operating manual en...

Page 2: ...trations of the digital display may be different from the illustrations in these instructions with regard to a few details However this does not have any influence on the operability of the digital di...

Page 3: ...ersonnel cause personal injury serious damage to machine or actuator Configuration commissioning mounting and maintenance by trained expert personnel only This personnel must be able to recognize dang...

Page 4: ...mm Resolution 0 05 mm 50 m Magnetic tape item no 3383979 Length in a piece 2000 mm Resolution 0 05 mm 50 m Magnetic tape item no 3383980 Bulk stock Resolution 0 05 mm 50 m 3 Installation 3 1 Mechanica...

Page 5: ...housings Contactor coils must be wired with spark suppression 3 2 1 Power supply speed sensor Power is supplied via the rear jack plug Connect the sensor for speed measurement from the scope of delive...

Page 6: ...peed display Counting resolution setting function Counting direction setting Linear error compensation Metric inches change over LCD display status setting Speed mode setting Basic value setting 4 1 K...

Page 7: ...the cursor to the specified options the PROG key is used to select For optional items using key to select and using the PROG key to exit after completing For modifying items using key to modify the d...

Page 8: ...and speed axis X axis parameter Three level menu press PROG key to enter to modify the X axis parameter Y axis parameter Three level menu press PROG key to enter to modify the Y axis parameter Z axis...

Page 9: ...ust be protected against environmental influences such as sprayed water solvent dust shocks vibra tions temperature fluctuations 5 4 Installation magnetic strip The mounting surface measuring track mu...

Page 10: ...e the system to magnetic fields Any direct contact of the magnetic strip with magnetic fields e g adhesive magnets or other permanent magnets is to be avoided Sensor movements during power loss are no...

Page 11: ...n This can be ignored if counting direction can be changed via the follower electronics Img 5 5 Definition of counting direction Distance measurements between sensor and magnetic tape and angular tole...

Page 12: ...h interference if necessary a protective screen or metal housing must be provided The running of wiring parallel to the mains supply should be avoided Contactor coils must be wired with spark suppress...

Page 13: ...tive read head MPA4 DRO5 no Read head different magnetic stripe differ ently DPA22 DRO5 no Connector differ ently active read head DRO3 DRO5 no Connector differently active read head DPM1 DRO5 no othe...

Page 14: ...ion display Type designation DRO 5 Year of manufacture __ __ __ __ Digital position display for using on machine tools for path measurement in conjunction with magnetic sen sors which meets all the re...

Reviews: