Optimum 3383975 Operating Manual Download Page 7

OPTIMUM

M A S C H I N E N   -   G E R M A N Y

Version 1.0.4  dated 2015-11-19

Page 21

Original operating instructions

DRO 5

GB

4.2

Operations

4.2.1 Axial function

In the normal display state, press (X,Y, Z) key to make the corresponding axial value flash.  After flash sev-
eral times, this axis will be cleared.
If the value of the indicator is blinking, press the corresponding axis button again to cancel the operation.
If the displayed value is in flashing state, press again the function button "PROG" in order to change the
fundamental value of the axis.

4.2.2 Modification of the basic value of X, Y, Z

After entering this option, the basic value is highlighted, and the digital bit is located in the flashing state.
The 

 

 keys are used for changing the digital bit, the  

 

 keys are used for selecting the digital bit. After

completing the changes, press the "PROG" key to exit the option.

5

MENU

The operating modes of the menus are nearly same. The 

 

 key move the cursor to the specified options,

the "PROG" key is used to select. For optional items, using  

 

 key to select, and using the "PROG" key to

exit after completing.  For modifying items,  
using 

 

 key to modify the digital bit, using  

 

 key to select the digital bit, using "PROG" key to exit after

completing. Pressing the "PROG" key in multilevel menus enters the next level menu.

5.1

The main menu

In the normal display state, press and hold the "PROG"  key for three seconds to enter the main menu.

LCD display setting

LCD display setting: the secondary menu, press "PROG"  key to enter to modify the LED display parameter.

Unit selection

Press "PROG"  key to enter the menu, mm/inch as a select.

Language selection

Press "PROG"  key to enter the menu, English/German as a select.

Working mode 

Press "PROG"  key to enter and select,

X    Y/Z0    Z
Standard display

X Z+Z0 Z
for lathes, Z / Z0 axis overlay display, Sum of be top slide

2X    Y/Z0    Z
for lathes, duplicate value in the X axis display.

Decimal point

Selection of decimal places, 2 or 3 decimal places.

Channel setup

Multilevel menus, press the "PROG" key to enter the menu, to modify X Y Z as well as the speed axial
parameter.

Summary of Contents for 3383975

Page 1: ...OPTIMUM M A S C H I N E N G E R M A N Y Dreiachs Positionsanzeige Three axes position display DRO 5 Artikel Nr Item no 3383975 Version 1 0 4 Betriebsanleitung de Operating manual en...

Page 2: ...trations of the digital display may be different from the illustrations in these instructions with regard to a few details However this does not have any influence on the operability of the digital di...

Page 3: ...ersonnel cause personal injury serious damage to machine or actuator Configuration commissioning mounting and maintenance by trained expert personnel only This personnel must be able to recognize dang...

Page 4: ...mm Resolution 0 05 mm 50 m Magnetic tape item no 3383979 Length in a piece 2000 mm Resolution 0 05 mm 50 m Magnetic tape item no 3383980 Bulk stock Resolution 0 05 mm 50 m 3 Installation 3 1 Mechanica...

Page 5: ...housings Contactor coils must be wired with spark suppression 3 2 1 Power supply speed sensor Power is supplied via the rear jack plug Connect the sensor for speed measurement from the scope of delive...

Page 6: ...peed display Counting resolution setting function Counting direction setting Linear error compensation Metric inches change over LCD display status setting Speed mode setting Basic value setting 4 1 K...

Page 7: ...the cursor to the specified options the PROG key is used to select For optional items using key to select and using the PROG key to exit after completing For modifying items using key to modify the d...

Page 8: ...and speed axis X axis parameter Three level menu press PROG key to enter to modify the X axis parameter Y axis parameter Three level menu press PROG key to enter to modify the Y axis parameter Z axis...

Page 9: ...ust be protected against environmental influences such as sprayed water solvent dust shocks vibra tions temperature fluctuations 5 4 Installation magnetic strip The mounting surface measuring track mu...

Page 10: ...e the system to magnetic fields Any direct contact of the magnetic strip with magnetic fields e g adhesive magnets or other permanent magnets is to be avoided Sensor movements during power loss are no...

Page 11: ...n This can be ignored if counting direction can be changed via the follower electronics Img 5 5 Definition of counting direction Distance measurements between sensor and magnetic tape and angular tole...

Page 12: ...h interference if necessary a protective screen or metal housing must be provided The running of wiring parallel to the mains supply should be avoided Contactor coils must be wired with spark suppress...

Page 13: ...tive read head MPA4 DRO5 no Read head different magnetic stripe differ ently DPA22 DRO5 no Connector differ ently active read head DRO3 DRO5 no Connector differently active read head DPM1 DRO5 no othe...

Page 14: ...ion display Type designation DRO 5 Year of manufacture __ __ __ __ Digital position display for using on machine tools for path measurement in conjunction with magnetic sen sors which meets all the re...

Reviews: