Version 1.0.2 - 2020-09-15
82
Translation of original instructions
GT25 | GT30 | GT40
EN
GT25_G
T30_G
T40_G
B_5-
1.
fm
Procedure
CAUTION!
Do not trap fingers between the table direction control arm and the stops!
Set speed lever L to the "STOP" position to stop the table feed.
Slide the stops D1 and D2 away from the table direction control arm C.
Use an open-end wrench to push the table direction control arm C off the axis S. Turn the S
axis until the proximity switch block touches the proximity switch and the red lamp lights up
(on-switch). Thus the axis S is in the correct position. Then reset the table direction control
arm C to the S axis.
Turn the speed lever L with your left hand until the table moves at low speed. Turn the table
direction control arm C with your right hand about 15-20 degrees to the right and left. This
should move the table to the right and left accordingly. If this is not the case, reset the table
direction control arm C to a different position on the axis and test the table movement direc-
tion accordingly until you find the correct position for the table direction control arm.
INFORMATION
If the table does not move smoothly, there may be air in the hydraulic line.
Also check whether the slideway oil of the central lubrication system reaches the lubrication
points.
Central lubrication supply points on page 33
To get the air out of the pipe, move the table for a moment at high pendulum speed.