Procedure
After switching on the control voltage, the system starts the oil supply and automatically repeats
the operating time and interval. When the pump is running this is indicated by a green LED. The
red LED lights up for the duration of the interval.
The flashing of ErO means that there is not enough oil.
The flashing of ErP indicates abnormal pressure.
If Ers flashes, it means that the system is overloaded.
INFORMATION
The higher the viscosity, the thicker the oil. The viscosity itself is not a quality characteristic, but
in connection with central lubrication systems it is suitable for adjusting a possibly too low or too
high slideway oil consumption without changing the interval and duration.
Make sure that the slideway oil used matches your process abrasive (coolant).
ISO VG 32 has a center point viscosity of 32 mm²/s at 40°C .
ISO VG 68 has a center point viscosity of 68 mm²/s at 40°C .
The shortest interval time should not be less than 2 minutes. After setting, press the SET button
to confirm.
The interval and duration have already been set appropriately by the factory before delivery.
ATTENTION!
The central lubrication prevents the so-called stick-slip effect, or the effect known as
stick-slip or jerk-slip between solids. Well-known examples are creaking doors or rattling
windscreen wipers. Make sure that no slipping occurs after some time if the lubrication
interval is changed.
Intervall [ min ]
Duration [ s ]
Duration [ s ]
Intervall [ min ]