fm
4.15
Condition electromagnet and hydraulic pump
The oscillation of the table by means of the hydraulics can only be activated if the electromag-
net is switched on first. If for some special operations it is necessary to work without an electro-
magnetic chuck (electromagnet), this function can be temporarily disabled in the <HMI>.
4.16
Displays in the HMI
This menu is used for testing and maintenance. The operator can monitor the input and output
conditions of the keys. The grey colour means 0 and green means 1 . For a special signal (nor-
mally closed) red means 0 and green means 1.
The two diagnostic pages are only available for testing and maintenance, the update time is
about 1 second.
4.16.1 Output signals