Opticon
OPL 9712
Specifications Manual
13
8.3.3.
Tilt Angle
Scanning performance is guaranteed when
γ
= ±20°
γ=
20
°
γ=
20°
Figure 6: Tilt angle
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
Distance:
90 mm from the edge of the data collector
Label:
Pitch, Skew Angle
PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39,
Quiet Zone = 10 mm, N/W Ratio = 1:2.5
Dead Zone, Tilt Angle
PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm
Angle:
Curvature: R =
∞
, Skew Angle =
β
+15° (for measuring Pitch Angle and Tilt Angle)