8.4. Curvature
With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when
R
≥
15 mm.
With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when
R
≥
20 mm.
Figure 7: Curvature
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm
Distance:
90 mm from the edge of the data collector
Angle: Skew
Angle
β
= +15°
The scanning range will vary according to the depth of field.