Opticon
NLV 2001
Specifications Manual
35
14. Reliability
MTBF (Mean Time Between Failures) of this product is 10,000 hours.
The estimate of MTBF and product life cycle is based on standard operation of the product
within the recommended temperature range and without extreme electronic or mechanical
shock.
15. Trigger and Read Options
The NLV 2001has read and trigger settings as follows:
15.1. Auto Trigger Sensor
When auto trigger is used, the scanner starts barcode reading after detecting a change in
reflection in the detection area. The scanner will be triggered if the sensors detect
changes in brightness in the detection area.
Auto trigger distance: 50 ±10 mm from the edge of the scanner.
Conditions
Moving speed:
100 ±10 mm/s
Angle:
Vertical to the edge of the scanner
Environmental temperature
and humidity:
Room temperature and humidity
Environmental illuminance:
500 to 900 lx
Conditions for the auto
trigger:
1. Barcode sheet: OPTOELECTRONICS Test Sheet (white)
Background: OPTOELECTRONICS Test Sheet (black)
2. Barcode sheet: OPTOELECTRONICS Test Sheet (black)
Background: OPTOELECTRONICS Test Sheet (white)
Figure 25: Auto trigger option (NLV 2001 I-Type)