Opticon
NLV 2001
Specifications Manual
11
The depth of field is measured from the front edge of the scanner.
PCS Resolution (mm)
Decode Depth (mm)
1.0 70–630
0.5 50–400
0.25 50–240
0.15 50–130
0.9
0.127 60–100
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
N/W Ratio
1:2.5
Angle
α
= 0°,
β
= 15°,
γ
= 0°
Curvature R
=
∞
Resolution Symbology
PCS
Quiet
Zone
Digit
1.0 mm
Code 39
0.9
25 mm
1
0.5 mm
Code 39
0.9
18 mm
3
0.25 mm
Code 39
0.9
10 mm
8
0.15 mm
Code 39
0.9
7 mm
10
0.127 mm
Code 39
0.9
5 mm
4