13. Durability
13.1. Electrical Noise
No malfunction occurred when sinusoidal electrical noise (50Hz -100kHz, < 0.1Vp-p) was
added to a power supply line.
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS 0.9
Resolution 0.25
mm
Symbology
9-digit Code 39
Quiet Zone
10 mm
N/W Ratio
1:2.5
Distance 150
mm
Angle
α
= 0°
β
= 15°
γ
= 0°
Curvature R
=
∞
Power Supply Voltage
5.0 V
13.2. Static Electricity
Air discharge
8 kV MAX (No malfunction)
10 kV MAX (No destruction)
Measurement environment
Use electrostatic testing device compliant with IEC 61000-4-2
Discharge resistance
330
Ω
Capacitor charging
150 pF
13.3. Shock: Drop Test
No malfunction occurred after the following drop test.
Drop Test: Drop the scanner from a height of 75 cm onto a concrete floor (three times in
each of 6 angles).
13.4. Vibration Strength
No malfunction occurred after the following vibration test.
Vibration test: Increase the frequency of the vibration from 10 Hz to 100 Hz with
accelerated velocity 19.6m/s
2
(2G) for 60 minutes in non-operating state. Repeat this
routine in each X, Y, Z direction once for 60 minutes each.
13.5. Dust and Drip Proof
IEC IP67
13.6. Cable Bending
Defects occurring due to bending the cable are not covered under warranty.