Troubleshooting
The display displays only black screen.
•
Check that all AC and DC plugs and jacks used by external power
supplies (both Opticis and others) are firmly connected.
•
Ensure that power is turned on.
•
Ensure that the Tx and Rx boxes plug correctly to the PC and display,
respectively.
•
Check if the PC and display are powered on and properly booted.
•
Re-boot up the system after reconnecting the optical system cable.
Screen is distorted or displays noises.
.
•
Reset the system.
•
Turn off, disconnect the LC-LC fiber cable and try to blow inside of
each LC receptacle by air blower
•
Reconnect the fiber cable and turn on.
•
If noise continues, please contact the following.
Maintenance
No special maintenance is required for the optical system cables and power
supplies. Ensure that the cables and power modules are stored or used in a
benign environment free from liquid or dirt contamination.
There are no user serviceable parts. Refer all service and repair issues to
Opticis or its authorized distributor.
Technical Support and Service
For commercial or general product support, contact your reseller. For
technical service, contact Opticis by email
or visit its
website at
www.opticis.com
.
1-7 Troubleshooting, Maintenance, Technical Support
Product Specifications
M1-3R2VI-DU Optical Dual Link DVI Module
Fully backward compatible with DVI standard:
supports DVI 1.0,
using fiber-optic communication links and DDC2B.
Extension limit:
100m (330feet) for 2,560x1,600 (1.65Gbps) with Direct DDC.
2km (6,560feet) for 2,560x1,600 (1.65Gbps) with Virtual DDC.
Graphic Transmission Bandwidth:
supports up to 1.65Gbps
bandwidth per graphic channel.
Fiber-optic Connection:
The transmitter and receiver boxes of M1-
3R2VI-DU have 2 duplex LC receptacles connected to four (4)
9(8)/125
µ
m Single-Mode or 62.5(50)/125
µ
m Multi-Mode glass fibers
cables.
Mechanical specifications of Tx and Rx boxes
Dimensions:
216mm / 31mm / 112mm (W/H/D)
Weight:
380
±
20 gr for each of Tx and Rx.
Environmental Specifications
Operating temperature: 0°C to 50°C
Storage temperature: -10°C to 85°C
Humidity: 5% to 85%
AC/DC Power Adapter
Power Input:
Universal AC 85-264V, 50/60Hz, AC power cord with
power jack.
Power Output:
+24 V, 2.5 A SMPS DC-power Adapter
Cord DC Jack & length:
Core is +24 V and outer cylinder is GND.
Length is 18.5 cm
AC Cord length: 1.8m
Certification
:
PSE, UL, cUL, FCC, CE, TUV-GS
1-8 Product Specifications