OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 13
2.3.2
DATA SWITCH SETTINGS
Six (SW1 to SW6) of the 8-way control switches are used for data control. The 8-way switch is located
at the front of OSD8327 modem.
FIGURE 9: DATA MODE SWITCH SETTINGS
TABLE 6: DATA MODE SWITCH SETTINGS
SWITCH
STATE
FUNCTION
SW1
OFF
RS232/RS422
ON
2 WIRE AND 4 WIRE RS485
SW5
OFF
NO BIAS RS485
ON
BIAS RS485
SW6
OFF
RS232/RS422 OR 4 WIRE RS485
ON
INVERSE RS232 OR 2WIRE RS485
Switches SW2, SW3 and SW4 are used for setting RS485 turnaround time.
TABLE 7: RS485 TURNAROUND TIME SWITCH SETTINGS
SW2
SW3
SW4
RS485 TURNAROUND TIME
ON
ON
ON
10us
ON
ON
OFF
30us
ON
OFF
ON
100us
ON
OFF
OFF
300us
OFF
ON
ON
1ms
OFF
ON
OFF
3ms
OFF
OFF
ON
10ms
OFF
OFF
OFF
30ms
STD 232/485
Bias
Delay
Delay
Delay
RS232/422/485
OFF
ON
1 2 3
4 5 6
7 8