background image

 

OPTICAL SYSTEMS DESIGN 

 

DOC ID: 10116601 

OSD8327 OPERATOR MANUAL

 

 

PAGE 17  

 

4

 

WARRANTY 

 

Thank you for purchasing equipment designed, manufactured and serviced by Optical Systems Design 
(OSD). OSD  warrants that at the time of  shipment, its products are free  from defects in  material and 
workmanship and conforms to specifications. Our Warranty conditions are outlined below: 

 
 
 

4.1

 

WARRANTY PERIOD 

 
For warranty period, please call your local OSD distributor. 
 

4.2

 

REPAIRS 

 
Optical  Systems  Design  reserves  the  right  to  repair  or  replace  faulty  modules/units.  Please  obtain  a 
“Return Material Authorisation” (RMA) form and number before returning goods. 
Goods  must  be  returned  in  adequate  packing  material  to  Optical  Systems  Design,  Warriewood  or  its 
nominated authorised representative, for all repairs. 
 
4.2.1

 

WARRANTY REPAIRS 

 
Return  shipments  to  OSD  shall  be  at  customer's  expense  and  freight  back  to  the  customer  will  be  at 
OSD expense. 
 
4.2.2

 

OUT-OF-WARRANTY REPAIRS 

 
OSD  reserves  the  right  to  repair  or  replace  any  faulty  goods.  Freight  costs  and  insurance  for  both 
journeys are met by the user. All equipment repaired by OSD will have a 3-Month Warranty from the 
date of dispatch.   
 
4.2.3

 

SITE REPAIRS 

 
By agreement site repairs may be undertaken for which out of pocket, hotel and travel expenses will be 
charged. 
 
4.2.4

 

EXCLUSIONS 

 
This  warranty  does  not  apply  to  defects  caused  by  unauthorized  modifications,  misuse,  abuse  or 
transport  damage  to  the  equipment.  All  modifications  to  OSD’s  standard  product  will  need  written 
authorization and will be charged at normal repair rates. All modifications are to be carried out by OSD 
Technicians.  Warranty  is  void  if  unauthorized  removal  and/or  tampering  with  serial  number  and/or 
labels is evident.  
 

Summary of Contents for OSD8327 Series

Page 1: ...OPERATOR MANUAL OSD8327 SERIES HD SDI AND DATA TX RX FIBER OPTIC TRANSMISSION SYSTEM...

Page 2: ......

Page 3: ...16 3 3 ROUTINE MAINTENANCE 16 4 WARRANTY 17 4 1 WARRANTY PERIOD 17 4 2 REPAIRS 17 4 2 1 WARRANTY REPAIRS 17 4 2 2 OUT OF WARRANTY REPAIRS 17 4 2 3 SITE REPAIRS 17 4 2 4 EXCLUSIONS 17 FIGURE 1 OSD8327...

Page 4: ...witch mounted on the front panel The OSD8327R has HD SDI received optical power LED indicators on the front panel displaying 0dBm 6dBm 12dBm 18dBm and 24dBm The OSD8327T and OSD8327R transmit and rece...

Page 5: ...l set up for an OSD8327 system FIGURE 1 OSD8327 TYPICAL CONFIGURATION OSD8327T OSD8327R 1 Fiber HD SDI Signal Source Monitor with HD SDI Interface Data Data OSD8327T OSD8327R 2 Fiber HD SDI Signal Sou...

Page 6: ...nal HD SDI Receiver Sensitivity 20dBm for 1x10 9 Bit Error Rate Data Link Transmitter Wavelength 1310nm 30nm or 1510 to 1590nm Data Link Transmitter Coupled Power 15 to 12dBm Data Link Receiver Sensit...

Page 7: ...point 2 2 2 WARNING AND PRECAUTIONS ELECTROMAGNETIC COMPATIBILITY WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be r...

Page 8: ...an even surface and to be secured by means of M4 or smaller screws The OSD8327T and OSD8327R card versions are designed to be inserted into a chassis and secured by means of captivated screws a Module...

Page 9: ...elow TABLE 2 OSD8327 DC POWER CONNECTION External Power Pin Specification Pin 1 Ground or 0V Pin 2 10 to 28VDC FIGURE 3 OSD8327 POWER SUPPLY CONNECTIONS 2 2 5 HD SDI CONNECTIONS The HD SDI video input...

Page 10: ...D8327R VIDEO CONNECTIONS 2 2 6 OPTICAL CONNECTIONS The optical fiber cable must be terminated with the appropriate optical connector Before connection inspect the ends of the connectors to ensure that...

Page 11: ...y one unit transmits data at a time All units are normally in high impedance receive mode waiting for data When transmission of data is requested the device waits for a protocol specific turn around t...

Page 12: ...has only the Reclocker switch SW8 The default setting is on position TABLE 4 OSD8327T SWITCH SETTINGS OSD8327T SWITCH STATE POSITION FUNCTION DEFAULT EQ OFF DOWN Automatic Equalizer Off ON UP Automat...

Page 13: ...TE FUNCTION SW1 OFF RS232 RS422 ON 2 WIRE AND 4 WIRE RS485 SW5 OFF NO BIAS RS485 ON BIAS RS485 SW6 OFF RS232 RS422 OR 4 WIRE RS485 ON INVERSE RS232 OR 2WIRE RS485 Switches SW2 SW3 and SW4 are used for...

Page 14: ...SDI source is off or unplugged Green Carrier Detected Locked Off Reclocker not locked or reclocker in bypass mode Green Reclocker is locked Transmit Data Off No data transmission Amber Data transmiss...

Page 15: ...No optical signal Off Optical Power above 27dBm 0dBm Green Optical Power above 0dBm 6dBm Green Optical Power above 6dBm 12dBm Green Optical Power above 12dBm 18dBm Green Optical Power above 18dBm 24d...

Page 16: ...circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when performing maintenance upon the unit 3 2 EXTERNAL INSPECTION...

Page 17: ...ative for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves t...

Page 18: ......

Page 19: ......

Page 20: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Reviews: