TECHNICAL SPECIFICATIONS 

 
 

TABLE 1: TECHNICAL SPECIFICATIONS 

 

SPECIFICATION 

PERFORMANCE 

Input/Output Impedance 

75

 

Input/Output Levels 

800mVpp nominal 

Coax Equalization 

350m @ 270Mbps 
140m @ 1.485Gbps 
70m @ 2.97Gbps 

SDI Connectors 

BNC Female Sockets 

Data Rate 

DC to 1Mbps NRZ 

Pulse Distortion and Jitter 

<±0.3

µ

sec over full dynamic range 

Input 

User selectable between RS422/RS485 levels, TTL on the + input 
with – input floating or RS232 levels 

User Controls 

8-way user adjustable lever switches 

HD/SDI Transmitter Wavelength 

1310nm ±30nm (1550nm optionally available) 

HD/SDI Transmitter Coupled Power 

-5 to -0dBm (0dBm and +2dBm are optional) 

HD/SDI Receiver Sensitivity 

<-20dBm for 1x10

-9

 Bit Error Rate 

Data Link Transmitter Wavelength 

1310nm ± 30nm or 1510 to 1590nm 

Data Link Transmitter Coupled 
Power 

-15 to –12dBm 

Data Link Receiver Sensitivity 

<-37dBm for 1 x 10

-9

 Bit Error Rate 

Standard Optical Link Budget 

>15dB at 1310nm (>30km of singlemode fiber) 

Optical Connector 

ST standard, FC and SC optional 

Power Requirements 

+10 to 28V

DC 

 

Electrical Connectors 

9 pin male subminiture D connector for power on card 
2 way terminal block with screw clamps for power on module 
8 way terminal block with screw clamps or data 

Dimensions (mm) 

 

100W x 208D x 25H card 
105 x 114 x 32 modem case 

Weight 

0.3kg (card), 0.8kg (modem case)  

Operating Temperature 

-20

°

C to +75

°

Relative Humidity 

0 to 95% non-condensing 

102832702 

NOTES: 
 

*Other combinations of laser types and optical levels, receiver types and sensitivity levels are 
possible. Contact OSD for details. 

Summary of Contents for OSD8327 Series

Page 1: ...OPERATOR MANUAL OSD8327 SERIES HD SDI AND DATA TX RX FIBER OPTIC TRANSMISSION SYSTEM...

Page 2: ......

Page 3: ...16 3 3 ROUTINE MAINTENANCE 16 4 WARRANTY 17 4 1 WARRANTY PERIOD 17 4 2 REPAIRS 17 4 2 1 WARRANTY REPAIRS 17 4 2 2 OUT OF WARRANTY REPAIRS 17 4 2 3 SITE REPAIRS 17 4 2 4 EXCLUSIONS 17 FIGURE 1 OSD8327...

Page 4: ...witch mounted on the front panel The OSD8327R has HD SDI received optical power LED indicators on the front panel displaying 0dBm 6dBm 12dBm 18dBm and 24dBm The OSD8327T and OSD8327R transmit and rece...

Page 5: ...l set up for an OSD8327 system FIGURE 1 OSD8327 TYPICAL CONFIGURATION OSD8327T OSD8327R 1 Fiber HD SDI Signal Source Monitor with HD SDI Interface Data Data OSD8327T OSD8327R 2 Fiber HD SDI Signal Sou...

Page 6: ...nal HD SDI Receiver Sensitivity 20dBm for 1x10 9 Bit Error Rate Data Link Transmitter Wavelength 1310nm 30nm or 1510 to 1590nm Data Link Transmitter Coupled Power 15 to 12dBm Data Link Receiver Sensit...

Page 7: ...point 2 2 2 WARNING AND PRECAUTIONS ELECTROMAGNETIC COMPATIBILITY WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be r...

Page 8: ...an even surface and to be secured by means of M4 or smaller screws The OSD8327T and OSD8327R card versions are designed to be inserted into a chassis and secured by means of captivated screws a Module...

Page 9: ...elow TABLE 2 OSD8327 DC POWER CONNECTION External Power Pin Specification Pin 1 Ground or 0V Pin 2 10 to 28VDC FIGURE 3 OSD8327 POWER SUPPLY CONNECTIONS 2 2 5 HD SDI CONNECTIONS The HD SDI video input...

Page 10: ...D8327R VIDEO CONNECTIONS 2 2 6 OPTICAL CONNECTIONS The optical fiber cable must be terminated with the appropriate optical connector Before connection inspect the ends of the connectors to ensure that...

Page 11: ...y one unit transmits data at a time All units are normally in high impedance receive mode waiting for data When transmission of data is requested the device waits for a protocol specific turn around t...

Page 12: ...has only the Reclocker switch SW8 The default setting is on position TABLE 4 OSD8327T SWITCH SETTINGS OSD8327T SWITCH STATE POSITION FUNCTION DEFAULT EQ OFF DOWN Automatic Equalizer Off ON UP Automat...

Page 13: ...TE FUNCTION SW1 OFF RS232 RS422 ON 2 WIRE AND 4 WIRE RS485 SW5 OFF NO BIAS RS485 ON BIAS RS485 SW6 OFF RS232 RS422 OR 4 WIRE RS485 ON INVERSE RS232 OR 2WIRE RS485 Switches SW2 SW3 and SW4 are used for...

Page 14: ...SDI source is off or unplugged Green Carrier Detected Locked Off Reclocker not locked or reclocker in bypass mode Green Reclocker is locked Transmit Data Off No data transmission Amber Data transmiss...

Page 15: ...No optical signal Off Optical Power above 27dBm 0dBm Green Optical Power above 0dBm 6dBm Green Optical Power above 6dBm 12dBm Green Optical Power above 12dBm 18dBm Green Optical Power above 18dBm 24d...

Page 16: ...circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when performing maintenance upon the unit 3 2 EXTERNAL INSPECTION...

Page 17: ...ative for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves t...

Page 18: ......

Page 19: ......

Page 20: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Reviews: