The  following  section  outlines  the  fault-finding  procedure  for  the  OSD2144A  modems.  Please  take 
note of the following: 
 

▲ 

Personnel  without  appropriate  training  should  not  attempt  any  maintenance  except  that  outlined 
below. 

 

▲ 

If further maintenance is attempted you are warned that every care should be taken to ensure that 
internal  measurements  made  while  the  equipment  is  operational  are  taken  carefully  as  some 
components within the unit are expensive and may be damaged by failure of any portion of their 
support circuitry. 

 

▲ 

Some  components  within  the  unit  are  Electrostatic  (ES)  sensitive  and  Electrostatic  Discharge 
(ESD) precautions should be taken when performing maintenance upon the unit. 

 
 

3.2

 

EXTERNAL INSPECTION 

 
 
Visually check for the following: 
 
 

▲ 

Check that the correct power source is connected to the power socket. 

 

▲ 

Check  that  the  Ethernet  cables  are  connected  to  the  modem  correctly  and  that  the  distant 
OSD2144A modem has been connected correctly to any external equipment.  

 

▲ 

Inspect  the  optical  connectors  (for  fiber  SFP  option)  for  any  contamination  and  clean  using 
isopropyl alcohol and a lint free tissue if any contamination is detected. 

 
 
 

3.3

 

ROUTINE MAINTENANCE  

 
 

▲ 

There is no routine maintenance required with the OSD2144A 

 

Summary of Contents for OSD2144A SERIES

Page 1: ...OPERATOR MANUAL OSD2144A SERIES 5 PORT UNMANAGED GIGABIT ETHERNET SWITCH...

Page 2: ......

Page 3: ...2 3 1 CONNECTIONS 14 2 4 FIRMWARE UPDATES 14 3 MAINTENANCE 15 3 1 INTRODUCTION 15 3 2 EXTERNAL INSPECTION 15 3 3 ROUTINE MAINTENANCE 15 4 WARRANTY 16 4 1 WARRANTY PERIOD 16 4 2 REPAIRS 16 4 2 1 WARRAN...

Page 4: ...the 20 C to 75 C temperature range which allows it to be used in uncontrolled environments such as roadside cabinets mine sites and factories 1 1 2 APPLICATIONS Any network utilising a mix of copper...

Page 5: ...IGURATION Figure 1 below indicates possible set ups for an OSD2144A system Point to Point Configuration Bus Configuration FIGURE 1 OSD2144A TYPICAL RING CONFIGURATION Network Switch PC Network Switch...

Page 6: ...er Wavelength 1310nm 30nm for 1000Base Lx or 100Base Fx 850nm 40nm for 1000Base Sx Transmit Optical Power 10dBm to 4dBm 5dBm and 2dBm 1310nm and 1550nm are optional Receiver Sensitivity 21dBm Standard...

Page 7: ...terminal block power connector while the card version consists of a DB9 power connector which is supplied by the OSD370 or OSD350 chassis A 4 Way DIP switch and micro USB connector are also on the rea...

Page 8: ...ct may cause radio interference in which case the user may be required to take adequate measures OPTICAL OUTPUT OPERATION WARNING Laser Safety Class 1 Laser Product per IEC EN 60825 1 20011 standard C...

Page 9: ...to be mounted on an even surface and to be secured by means of M4 or smaller screws The OSD2144A card version is designed to be inserted into a chassis and secured by means of captivated screws a Modu...

Page 10: ...ation Power should be connected to the power socket located at the back of the case as indicated in Table 2 TABLE 2 DC OR AC POWER CONNECTION External Power Pin Specification Pin 1 and or 5 8VDC to 35...

Page 11: ...ctivity No Link 1Gbps 100Mbps 10Mbps Full Duplex Half Duplex On On No Activity Activity No Link 1Gbps 100Mbps 10Mbps Full Duplex Half Duplex On On Power On Power Off On No Activity Activity No Link 1G...

Page 12: ...4 WAY DIP SWITCH TABLE 4 OSD2144A 4 WAY DIP SWITCH SETTINGS SWITCH NUMBER DESCRIPTION FUNCTION SWITCH POSITION 1 Port 5 Fiber Speed 1000Mbps 100Mbps OFF ON 2 Port 4 Fiber Speed 1000Mbps 100Mbps OFF O...

Page 13: ...e SFP is fully engaged and latched into position Inserting SFP Ensure that the SFP lever is in the locked position and insert into appropriate SFP port Gently push the SFP until it locks into place Re...

Page 14: ...or higher Length should be no more than 100 meters For singlemode fiber connections fiber used must be 9 125 m singlemode fiber For multimode fiber connections fiber used must be 50 or 62 125 m multim...

Page 15: ...e damaged by failure of any portion of their support circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when performin...

Page 16: ...tive for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves th...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Reviews: