3

 

MAINTENANCE 

 

3.1

 

INTRODUCTION 

 
 
The following section outlines the fault-finding procedure for the OSD2010 modems. Please take note 
of the following: 
 

▲ 

Personnel  without  appropriate  training  should  not  attempt  any  maintenance  except  that  outlined 
below. 

 

▲ 

If further maintenance is attempted you are warned that every care should be taken to ensure that 
internal  measurements  made  while  the  equipment  is  operational  are  taken  carefully  as  some 
components within the unit are expensive and may be damaged by failure of any portion of their 
support circuitry. 

 

▲ 

Some  components  within  the  unit  are  Electrostatic  (ES)  sensitive  and  Electrostatic  Discharge 
(ESD) precautions should be taken when performing maintenance upon the unit. 

 
 

3.2

 

EXTERNAL INSPECTION 

 
 
Visually check for the following: 
 
 

▲ 

Check that the correct power source is connected to the power socket. 

 

▲ 

Check that the SFPs are connected to the modem correctly.  

 

▲ 

Inspect the optical connectors for any contamination and clean using isopropyl alcohol and a lint 
free tissue if any contamination is detected. 

 

▲ 

Check  that  any  external  termination  resistors  are  connected  if  the  system  configuration  requires 
them. 

 
 

3.3

 

ROUTINE MAINTENANCE  

 
 

▲ 

There is no routine maintenance required with the OSD2010. 

 

Summary of Contents for OSD2010

Page 1: ...OPERATOR MANUAL OSD2010 FIBER MODE CONVERTER...

Page 2: ......

Page 3: ...DICATORS 10 2 3 4 FITTING SFP CONNECTORS 11 3 MAINTENANCE 12 3 1 INTRODUCTION 12 3 2 EXTERNAL INSPECTION 12 3 3 ROUTINE MAINTENANCE 12 4 WARRANTY 13 4 1 WARRANTY PERIOD 13 4 2 REPAIRS 13 4 2 1 WARRANT...

Page 4: ...r Adding CWDM to an existing fiber network Extending optical transmission distances by operating as an optical repeater Networks using Ethernet devices such as cameras intercoms access control telepho...

Page 5: ...Please consult OSD SFP datasheets or contact OSD Alarms SFP 1 Laser Fail SFP 1 Loss of Received Optical Signal SFP 2 Laser Fail SFP 2 Loss of Received Optical Signal Alarm Interface 4 Open drain outpu...

Page 6: ...se radio interference in which case the user may be required to take adequate measures OPTICAL OUTPUT OPERATION WARNING Laser Safety Class 1 Laser Product per IEC EN 60825 1 2014 standard Class 1 The...

Page 7: ...PAGE 7 2 2 2 OSD2010 DRAWINGS AND DIMENSIONS The OSD2010 is designed to be mounted on an even surface and to be secured by means of M4 or smaller screws FIGURE 2 OSD2010 MOUNTING DIMENSIONS R2 1 R2 1...

Page 8: ...cated at the back of the case DC power should be connected as indicated in Table 2 TABLE 2 DC OR AC POWER CONNECTION Power Pin Specification Pin 1 10V to 36VDC or 22V to 28VAC Pin 2 0V Pin 3 10V to 36...

Page 9: ...1 0V Ground Pin 2 Laser Ch A Fail Ch A Short to GND Pin 1 when OK Ch A Open Circuit when not OK or Power off Pin 3 Rx Ch A Fail Ch A Short to GND Pin 1 when OK Ch A Open Circuit when not OK or Power...

Page 10: ...E 4 INDICATOR FUNCTION LED Specification Parameter Ch A Receive Signal OK Red No Received Signal Green Received Signal OK Ch A Laser OK Red Transmit Laser Fail Green Transmit Laser OK Ch B Receive Sig...

Page 11: ...nstalling Ensure that the SFP is fully engaged and latched into position Inserting SFP Ensure that the SFP lever is in the locked position and insert into appropriate SFP port Gently push the SFP unti...

Page 12: ...and may be damaged by failure of any portion of their support circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when...

Page 13: ...ative for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves t...

Page 14: ......

Page 15: ......

Page 16: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Reviews: