18
5.4 Remote Control
The SP8000 AVR can be set for daily shutdown/wake up. This command must be set through the
RS-232 interface. When this function is set, the timer inside the Inverter will begin to run, and the
load will be turned off by the shutdown / wake-up schedule. The time period to next turn-on will be
shown on LCD panel by hour (Ref. item 15 of LCD description).
For the application of timer, the monitoring software, UPSilon, and the green cable are both required.
5.5 Reset the Inverter
If any abnormal condition occurs, and the item 4.1 ~ 4.7 can not be executed, please unplug the
line cord and push the button for at least 15 sec., which will reset the Inverter.
5.6 DIP Switch Settings
OFF / Up
ON / Down
DIP 1
High Sensitivity for Blackout
Low Sensitivity for Blackout
DIP 2
5% AVR
8% AVR
DIP 3
2-stage Charging
CV Charging
DIP 4
Green mode Enabled
Green mode Disabled
5.7 DB9 Dry Contact
Blackout
Low Battery Alarm (42.4Vdc)
PIN 2
-
NC
PIN 3
NC
-
PIN 6
-
N
PIN 7
-
NO
PIN 8
N
-
PIN 9
NO
-