59
3.
Float stage: Constant voltage charging with lower voltage
Charging/Discharging Parameters
Type
Ah
Buck
Charging
Current
Absorption
Voltage
Float Voltage
Cut-off
Voltage
G
en
er
ic
100
20
14.1
13.7
10.8
200
40
14.1
13.7
10.8
300
60
14.1
13.7
10.8
400
80
14.1
13.7
10.8
≥500
100
14.1
13.7
10.8
Yua
sa
N
PA
100
-12I
100
25
14.5
13.7
10.2
200
50
14.5
13.7
10.2
300
75
14.5
13.7
10.5
400
100
14.5
13.7
10.5
≥500
100
14.5
13.7
10.5
Chl
or
ide
12C
DC
100
100
20
14.7
13.7
10.2
200
40
14.7
13.7
10.2
300
60
14.7
13.7
10.5
400
80
14.7
13.7
10.5
≥500
100
14.7
13.7
10.5
3K
EB
B
100
100
20
14.4
13.7
10.2
200
40
14.4
13.7
10.2
300
60
14.4
13.7
10.5
400
80
14.4
13.7
10.5
≥500
100
14.4
13.7
10.5
Pa
na
son
ic
LC
-T12015
100
30
14.5
13.7
10.2
200
60
14.5
13.7
10.2
300
90
14.5
13.7
10.5
400
100
14.5
13.7
10.5
≥500
100
14.5
13.7
10.5
Note:
1.
The voltage indicated is for single 12V battery
2.
Cut-off voltage is the stop voltage of rated discharging power. E.g. for one string, it is the
voltage of 115A discharging