PARTS IDENTIFICATION
3
INSTALLATION METHOD
4
WIRING
5
SENSITIVITY ADJUSTMENT
6
ZOOM AREA ADJUSTMENT
7
INITIAL ALARM MEMORY & ALARM MEMORY (SX-360ZV)
8
PULSE COUNT ADJUSTMENT
9
SX-360Z
SX-360ZV
Main unit
Zoom unit
Screw
Pulse count selector
(See section 9.)
LED ON/OFF switch
(See section 10.)
Sensitivity selector
(See section 6.)
Wiring knockout
Wiring knockout
Wiring knockout
LED indicator
Pyro sensor
Do not touch.
Terminals
Wiring knockout
Screw
Mounting holes
Pitch 83.5 mm
(3.28 inch)
LED indicator for
Zoom ring
Zoom lens
SPARE
TAMPER
D.L. (See section 10.)
N.C.
TAMPER
D.L. (See section 10.)
(See section 8.)
(See section 8.)
N.C.
ALARM OUTPUT
ALARM MEMORY
ALARM OUTPUT
POWER INPUT
INITIAL ALARM MEMORY
SPARE
Two spare terminals
are electrically
connected on the
circuit board.
SPARE
POWER INPUT
Warm-up period
Alarm
Alarm memory
Initial alarm memory
Remove the Zoom-unit from
the Main unit by loosening
the screw and turning the
Zoom unit counter-clockwise.
Before making adjustments, determine the mounting
height and detection area. (See section 7.)
Select the sensitivity “H (High)”, “M (Medium)” or “L (Low)”.
The following chart shows recommended setting for diameter
of detection area.
SENS.
L
ø9.0 to ø12 m
(ø30 to ø40 ft.)
ø12 to ø15 m
(ø40 to ø50 ft.)
ø15 to ø18 m
(ø50 to ø60 ft.)
M
H
DIAMETER OF
DETECTION AREA
Note>>
• When the warm-up period is expired, alarm is generated once. This is an electric characteristic of SX-360Z and not a mal-function.
• Conduct a walk test at least once a year.
Mount the Main unit
and wire according to
section 5.
Full up the mounting
holes with the sponge.
Adjust Zoom (section
7) and Sensitivity (section
6) according to the
required installation
height.
Install the Zoom unit
by turning it clockwise.
And supply power to
the detector.
When LED stops blinking,
the warm-up period is
expired (approx. 20 sec.). Conduct a walk test.
Select pulse count (see
section 9.) according to
your coverage needs and
environmental conditions.
And then fasten the screw.
Power wires should not exceed the following lengths.
VOLTAGE
WIRE SIZE
AWG22 (0.33 mm
2
)
12V
SX-360Z
SX-360ZV
14V
12V
14V
320 m (1070 ft)
650 m (2140 ft)
230 m (770 ft)
460 m (1530 ft)
730 m (2400 ft)
1150 m (3800 ft)
360 m (1200 ft)
570 m (1900 ft)
1020 m (3400 ft)
1600 m (5300 ft)
510 m (1700 ft)
820 m (2700 ft)
AWG20 (0.52 mm
2
)
AWG18 (0.83 mm
2
)
UL requires SX-360Z to be connected to a UL listed power supply capable of providing a nominal input of 12 VDC and battery standby time of 4 hours.
When using two or more units on one wire, the maximum length is obtained by dividing the above length by the number of units used.
2.4 to 5.0 m
(8.0 to 16 ft.)
ø9.0 to ø18 m
(ø30 to ø60 ft.)
1
1
2
2
3
1
1
3
2
3
4
5
6
Zoom ring
Turn Zoom ring for adjustment.
Zoom lens
Loosen the black Zoom Lock screw.
For higher installations, turn counter-clockwise.
Fasten the black Zoom lock screw at the
marked point of the required installation
height.
For lower installations, turn clockwise.
The SX-360Z series detection pattern can be adjusted for installations at any height, between 2.4 to 5.0 m (8.0 to 16 ft.)
DETECTION AREA CHART
ADJUSTING THE ZOOM UNIT
Unit: m (ft.)
The SX-360ZV can indicate an alarm history during armed period by wiring ALARM MEMORY terminal (A.M.) shown in the following section.
It indicates on the LED after the system is disarmed. In case that several detectors are connected in one loop, it can indicate which one detected
intrusions. In addition, by wiring INITIAL ALARM MEMORY terminal (I.A.), detectors can indicate which one detected intrusion first.
System status
2
Reset
Wiring and LED indications
Adjust pulse count as follows.
System armed
Control panel output
Status
0 - 1 VDC (grounded)
Open
System disarmed
“grounded”= A.M. terminal is electrically connected with power
supply terminal (ground).
Instant alarm mode
Select this position for walk test only.
Factory default position
Select this position for most applications.
For bad environments, changing
temperatures etc.
Alarm memories are reset automatically when the system is armed again.
A
MOUNTING HEIGHT
ZOOM-LOCK SCREW
5.0 m (16 ft.)
4.3 m (14 ft.)
3.7 m (12 ft.)
ø9.0 (ø30)
3.0 m (10 ft.)
2.4 m (8.0 ft.)
ø18 (ø60)
ø16 (ø52)
ø14 (ø48)
ø11 (ø37)
B
ø10 (ø34)
-
ø18 (ø60)
ø15 (ø50)
ø12 (ø40)
C
ø12
D
ø15
E
ø18
-
-
-
-
-
-
-
ø18
-
-
ø18
ø15
I.A. A.M.
I.A. A.M.
I.A. A.M.
Note>>
• Up to
40 detectors can be connected in one loop
for initial alarm memory.
Control
Panel
I.A. A.M.
I.A. A.M.
I.A. A.M.
Note>>
• Do not fasten the screw too tightly.
Note>>
• A suitable control panel is required for alarm memory.
• Alarm memory is operated whether the LED is disabled or not.
• Alarm memory is not latched while system is disarmed.
• LED operation and alarm output are not affected by the status of alarm
memory function while system is armed.
A.M.
A.M.
I.A.
Disarmed
1
1
2
3
No.
LED
OFF
Blinking
Lighting
2
3
Initial alarm memory is shown by a blinking LED. Other memories
(from the second detection on) are shown by a lighting LED.
All alarm memories are shown by blinking LED.
LED indications
Wiring
Function
Alarm
memory
Initial alarm
memory
1
2
3
No.
LED
OFF
Blinking
Blinking
Control
Panel
Disarmed
1
2
3
PULSE COUNT
TEST
2
4
USAGE
The detector recognizes whether the system is armed or
disarmed by detecting the voltage of control panel output
through the A.M. terminal.
Control
Panel
Control
Panel
Main unit