360° CEILING MOUNT PASSIVE INFRARED DETECTOR
SX-360Z, SX-360ZV
INSTALLATION HINTS
1
DETECTION AREA
2
SPECIFICATIONS
12
FEATURES
Ceiling mount 360° PIR detector
Zoom area adjustment : ø18 m (ø60 ft.) at 2.4 –5.0 m (8 –16 ft.)
High density detection area with 276 zones
Selectable sensitivity (High, Medium or Low)
Selectable pulse count (TEST, 2 or 4)
Initial alarm memory (SX-360ZV)
LED remote control terminal
TOP VIEW
SIDE VIEW
9.0
(30)
9.0
(30)
9.0
(30)
0
0
6.0
(20)
6.0
(20)
6.0
(20)
6.0
(20)
ZOOM
ZOOM “A” Position (See Section 7.)
Model
SX-360Z
Detection method
Passive Infrared
276 zones
Celling
ø18 m (ø60 ft.) at 2.4 –5 m (8 –16 ft.)
360° ZOOM
LED is blinking during warm-up period.
Alarm condition
2.0 ±0.5 sec.
N.C., 28 VDC 0.2 A (max.)
N.C., Opens when cover removed.
20 ±5 sec. 1, 2 or 4
Approx. 20 sec. (LED blinks.)
9.5 to 18 VDC
16 mA/(normal), 18 mA/(max.)
224 g (7.90 oz)
–20°C to +50°C (–4°F to +122°F)
95% (max.)
No Alarm 30 V/m
Detection zones
Mounting location
Coverage / Mounting
height
Optical design
LED indicator
Alarm period
Alarm output
Tamper switch
30 V DC 0.1 A (max.)
Tamper output
Pulse Count
Warm up period
Power input
Current draw
Weight
Operating
temperature
Environment humidity
RF interference
Dimensions
mm (inch)
mm (inch)
67(2.64)
- 73(2.88)
45.5 (1.79)
46.5 (1.83)
6
(0.23)
20°
30°
12
(0.47)
ø128(ø5.04)
Mounting Position
Flush
wiring knockout
Pitch ø83.5 (ø3.29)
ø6.5 (ø0.26)
Wall tamper knockout
8.5 (0.33)
Mounting
holes
Flush wiring knockout
12
(0.47)
12
(0.47)
20°
Terminals
Surface wiring knockout
* Specifications and design are subject to change without prior notice.
ø8.5
(ø0.33)
4.5 (0.18)
Surface
wiring knockout
Flush
wiring space
Model
SX-360ZV
Alarm memory
Armed : 0 to 1 VDC. See section 8.
Initial Alarm memory
Max.40 detectors See section 8.
Current draw
16 mA/(normal), 28 mA/(max)
Weight
227 g (8.00 oz.)
RF interference
No Alarm 30 V/m
ZOOM
Unit: m (ft)
ZOOM “E” Position (See Section 7.)
ZOOM “C” Position (See Section 7.)
LED ON-OFF
10
The LED can be enabled or disabled by using the LED ON/OFF
switch or by using D.L. terminal.
1
LED ON/OFF Switch (SX-360Z only)
2
DL Terminal (for LED remote control)
TROUBLE SHOOTING AND MAINTENANCE
11
PROBLEM
PROBABLE CAUSE
REMEDY
LED does not light.
LED lights even
though no person
within area.
LED continues to
light
LED lights but signal
is not sent.
Correct supply voltage to
9.5 - 18 VDC.
Incorrect power supply voltage.
(disconnection, or low voltage)
See section 2 and section 7.
Switch positive and negative at
terminal.
Turn on the Switch. See section 10.
Remove object from detection
area.
Remove object from detection area.
Reconnect wire.
Must be 0 to 1 VDC. (grounded)
Check load of output. The unit
needs repair or replacement.
Wire correctly.
Incorrect detection area.
Incorrect polarity to detector.
LED switch is OFF
Moving object within area. (curtain,
wall hanging, etc.)
Rapid temperature changes (heater,
air-conditioner, etc.) within area.
Poor connection of alarm memory.
(SX-360ZV)
Wrong control voltage from panel.
(SX-360ZV)
Relay contact is stuck of damaged
due to overloading.
Faulty Wiring.
No.59-0527-8 150707
UL 59-0527-6 0908-31
EN
Avoid direct sunlight.
Avoid facing directly
to air conditioners or
heating vents.
Avoid vapor or high
humidity that can
cause condensation.
Install within 2.4 to 5.0 m (8.0 to 16 ft.)
height from floor.
2.4 to 5.0 m
(8.0 to 16 ft.)
Do not install outdoors.
Do not obscure partially or
completely the detector’s
field of view.
1
4
5
3
6
7
Avoid moving objects in the
detection area.
2
This symbol indicates
prohibition.
This symbol indicates
recommendation.
2.4(8.0)
4.2(14)
4.8(15)
3.6(12)
3.0(10)
2.4(8.0)
3.0(10)
6.0(20)
9.0(30)
3.0(10)
6.0(20)
9.0(30)
0
3.6(12)
3.0(10)
2.4(8.0)
3.0(10)
6.0(20)
9.0(30)
3.0(10)
6.0(20)
9.0(30)
0
3.0(10)
6.0(20)
9.0(30)
3.0(10)
6.0(20)
9.0(30)
0
• Use this switch to enable or disable LED.
• This switch has priority to over DL terminal.
• LED can be enabled or disabled remotely by using
DL terminal.
LED Enabled
Connect DL terminal to common ground.
Open DL terminal circuit.
Remote operation
LED Disabled
Note>>
•
LED operation does not affect the alarm memory functions.
•
DL terminal common line is same as terminal of POWER INPUT.
COMPLIANCE
13
• This unit is designed to detect movement of an intruder and activate an
alarm control panel. Being only a part of a complete system, we cannot
accept responsibility for any damages or other consequences resulting
from an intrusion.
• This Product conforms to the EMC Directive. 2004/108/EC.
• The ULC products are installed in accordance with the Canadian Code
as per Section 4.3 of ULC-S306.
EMC Directive
2004/108/EC
EN 50130-4: 2011
EN 55022: 2010
(SX-360Z)
EN50131-1 Grades and Environmental Class:
Security Grade 2 and Environmental Class II.
EN 50131-2-2
Tested and certified by Telefication.
larm klass 2, miljö klass II, SSF 1014 v4
UL/c-UL Listed
PD6662:2010
Note>>
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net/
OPTEX INC. (U.S.)
URL: http://www.optexamerica.com/
OPTEX DO BRASIL LTDA. (Brazil)
URL: http://www.optex.net/br/es/sec/
OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)
URL: http://www.optexeurope.com/
OPTEX SECURITY SAS (France)
URL: http://www.optex-security.com/
OPTEX SECURITY Sp.z o.o. (Poland)
URL: http://www.optex.com.pl/
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
URL: http://www.optexchina.com/
OPTEX KOREA CO.,LTD. (Korea)
URL: http://www.optexkorea.com/
OPTEX PINNACLE INDIA, PVT., LTD. (India)
URL: http://www.optex.net/in/en/sec/
OPTEX TECHNOLOGIES B.V.
(The Netherlands)
URL: http://www.optex.eu/