background image

- 8 -

- 9 -

ENGLISH

FRANÇAIS

DEUTSCH

IT

ALIANO

ESP
AÑOL

Area B

Area A

0

8

6

24

4

2

20

28

0

4

8

2

6

20

24

28

7

F

Fine

adj.

Area A

-  +

-  +

Area B

Range

0

8

6

24

4

2

20

28

0

4

8

2

6

20

24

28

7

F

Offset

-   0

Set

A2

Set

A2

Power

A B B2

Status

REDWAVE

REDWAVE

MICROWAVE

REDWAVE

ALARM OUTPUT

CELL BATTERY
POWER

SUPPLY

FROM

SENSOR

POWER OFF

REDWAVE

PIR NEAR

REDWAVE

PIR FAR

MEGARED

FAR

MEGARED

NEAR

REDWALL

REDWIDE

WALKTESTER

REDWALL

REDWIDE

MEGARED

CONNECTION

SELECT

SWITCH

MODE

SELECT

SWITCH

POWER

SELECT

SWITCH

OPM-WT

2

Auto

P
P2

-Selecting the detection sensitivity

H Manual H Auto

H2 Manual H2 Auto

V Auto

Set the detection sensitivity using the Size selector switch and 

Sens. selector switch. You can set the detection sensitivity in the 

horizontal area with the size of the target object and its move 

distance within the detection area.

H

M

L

S

M

L

Size

Sens.

SELECTOR

POSITION

FUNCTION

S

Approx. 50 mm 

(0.5 ft.) or above

This switch 

specifies 

the width of 

the target 

object to be 

detected.

M

Approx. 300 mm 

( ft.) or above

L

Approx. 000 mm 

(3.3 ft.) or above

H

Approx. 500 mm 

(.6 ft.) or above

This switch 

specifies 

the move 

distance of an 

object in the 

detection area 

above which 

it is judged as 

an intruder.

M

Approx. 000 mm 

(3.3 ft.) or above

L

Approx. 2000 mm 

(6.6 ft.) or above

5-2 MANUAL SETTING OF HORIZONTAL DETECTION AREA

H Manual H Auto

H2 Manual H2 Auto

V Auto

Set a fan-like detection area using the rough alignment rotary 

switch and fine alignment potentiometer.

-Rough alignment rotary switch

You can specify the radius in the range of 0 to 30 m in 2 m steps.

Setting the rough alignment rotary switch to 0 m deletes the area.
Example: if you specify “Detection distance in Area A: 30 m” 

and “Detection distance in Area B: 4 m” in a location where the 

radius is 30 m or more without a reflector, the following detection 

areas will result.

SELECTOR 

POSITION (m)

[ft.]

0

0

4

3

8

26

2

39

6

52

20

65

24

79

28

92

-Fine alignment potentiometer

This potentiometer can fine tune the value set with the rough 

alignment rotary switch by +/-  m. within the range of 0 m 

minimum and 30 m maximum.

Setting done in rough 

alignment

Range available for fine alignment

When 0 m is set

0 to + m (From - to 0 m on the scale 

is not usable)

When 2 to 28 m is set

± m

When 30 m is set

- to 0 m (From 0 to + m on the scale 

is not usable)

-Offset adjustment

You can reduce a set detection area using the offset 

potentiometer. Use this adjusting function when windblown grass 

or tree branches interfere with the currently set detection area.
You can adjust the boundary of a given detection area inward 

(toward the sensor) in the range of 0 to - m.

5-3 STARTING SECURITY PROTECTION IN MANUAL MODE

H Manual H Auto

H2 Manual H2 Auto

V Auto

When “Manual” is chosen from the mode selector 

switch, turning the power on starts the security 

protection in manual mode.

5-4 AUTO SETTING OF HORIZONTAL DETECTION AREA

-Function of the detection area setting button

H Manual H Auto

H2 Manual H2 Auto

V Auto

This button starts the auto function of either P or 

P2 whichever has been selected.

-Setting P1 (Auto Learning)

H Manual H Auto

H2 Manual H2 Auto

V Auto

Sequence of 

operation

Status 

indicator

Time

Action of REDSCAN/

Response of Walk Tester

Hold down the 

detection area setting 

button for  second.

Flashing 

starts

For 

 second

Pitch of Walk Tester 

sound changes for 

2 seconds

2

Evacuation from 

the area

Flashing (*)

For 

5 seconds

Fast flashing 

(*2)

For 

0 seconds

Scan of the detection 

area is executed

ON

For 

5 seconds

Scan of the detection 

area is completed and 

the data are saved

Flashing

For 

3 seconds

OFF

Security protection of the 

detection area is started

*:  Flashes once a second

*2:  Flashes twice a second

Cautions >>

Do not enter the area while the area scan is being carried 

out. 

An unwanted object in the area interferes with the correct 

scanning of the target area.

Offset

Offset

Auto P (Auto Learning)

Manual Mode

Area

B2

Area

B

Area

A

Area

A2

5 m

7 m

30 m

4 m

: Detection area

Summary of Contents for RLS-3060

Page 1: ...duct is wet with rain etc It may cause electric shock Never attempt to disassemble or repair the product It may cause fire or damage to the devices Do not exceed the voltage or current rating specifie...

Page 2: ...period 36 s Standard IEC60825 1 Class 1 of the Laser Safety Standard means that the safety of laser products belonging to this class is warranted under normal operating conditions reasonably predictab...

Page 3: ...epending on which detection method of either H1 H2 or Vertical detection Area is selected Horizontal Detection Area 1 Horizontal Detection Area 2 Manual In this mode set up a detection area by specify...

Page 4: ...the angle so that the inclination in the horizontal plane becomes parallel to the ground Cautions When installing the product to the wall fix the mounting bracket parallel to the ground If the mounti...

Page 5: ...nit and fix it to the mounting bracket Adjust the angle so that the inclination in the vertical direction becomes parallel to the ground 5 Take steps 6 through 9 in 3 1 to do wiring check the setup an...

Page 6: ...g the product at an angle to a wall attach the paper template attached to the main unit to the wall and drill 4 mounting holes in it in the same way as described in 3 1 3 For the ceiling plane follow...

Page 7: ...Upon detecting an intruder this product outputs the alarm specific to the area Area A1 Area A2 Area B1 or Area B2 where the intrusion happened When combined with an area monitoring system using a PTZ...

Page 8: ...ed Area A1 alarm output B1 Red Area B1 alarm output B2 Red Area B2 alarm output Status Yellow Lit during auto setup of the unit Turned off during normal operation Power Green Lit when power is turned...

Page 9: ...20 65 24 79 28 92 Fine alignment potentiometer This potentiometer can fine tune the value set with the rough alignment rotary switch by 1 m within the range of 0 m minimum and 30 m maximum Setting don...

Page 10: ...d selection H1 Manual H1 Auto H2 Manual H2 Auto V Auto Select the desired method using the detection method selector switch Func H V H2 SELECTOR POSITION FUNCTION H1 H2 V Selects the vertical detectio...

Page 11: ...al H1 Auto H2 Manual H2 Auto V Auto Ensure that the detection area has been correctly set referencing the red indicator and changes in the pitch of Walk Tester sound When a detection area has not been...

Page 12: ...wer Green LED Area alarm output N O 28V DC 0 2A 4outputs Master alarm output Form C 28V DC 0 2A max Trouble output Form C 28V DC 0 2A max Tamper output N C 28V DC 0 1A max Environmental disqualificati...

Reviews: