- 8 -
- 9 -
REDWAVE
REDWAVE
MICROWAVE
REDWAVE
ALARM OUTPUT
CELL BATTERY
POWER
SUPPLY
FROM
SENSOR
POWER OFF
REDWAVE
PIR NEAR
REDWAVE
PIR FAR
MEGARED
FAR
MEGARED
NEAR
REDWALL
REDWIDE
WALKTESTER
REDWALL
REDWIDE
MEGARED
CONNECTION
SELECT
SWITCH
MODE
SELECT
SWITCH
POWER
SELECT
SWITCH
OPM-WT
Set
A2
Power
A B B2
Status
Set
A2
Power
A B B2
Status
Fine
adj.
Auto Func. Set
P
P2
H
V
H2
Offset
Sens.
H
M
L
Size
S
M
L
Area A
A2
Power
- +
- +
- 0
A B B2
Area B
573240
Status
Range
Mode
M
A
0
8
6
24
4
2
20
28
0
4
8
2
6
20
24
28
7
7
Fine
adj.
Auto Func. Set
P
P2
H
V
H2
Offset
Sens.
H
M
L
Size
S
M
L
Area A
A2
Power
- +
- +
- 0
A B B2
Area B
573240
Status
Range
Mode
M
A
0
8
6
24
4
2
20
28
0
4
8
2
6
20
24
28
7
7
Set
A2
Power
A B B2
Status
SETTING HORIZONTAL DETECTION AREAS AND 2
5
4-4 CONNECTING WALK TESTER
1
Turning on the power selector switch after plugging
the cable into the Walk Tester Connector generates a
continuous beep at a constant sound level.
2
The beep sound becomes stronger and continues for a
longer period if an object is detected.
4-5 POWERING ON
Connect 24 VAC/DC to the power input terminal to
turn power on.
As power is turned on, the indicators (A, A2, B,
B2, Status and Power) light for about 30 seconds
and then go out.
During this period, REDSCAN initializes itself.
Indicator Power remains lit as long as power is
turned on.
Legend
OFF
Light
Blink
4-6 SWITCH LAYOUT
4-7 LED FUNCTIONS
-In the normal operation
Symbol
Color
DETECTOR STATUS
A2
Red
Area A2 alarm output
A
Red
Area A alarm output
B
Red
Area B alarm output
B2
Red
Area B2 alarm output
Status
Yellow
Lit during auto setup of the unit.
(Turned off during normal operation.)
Power
Green
Lit when power is turned on
-When an abnormality occurs
Status
A2 A B B2 Status Power
D.Q.
Anti-masking
Anti-rotation
Sensor
error
Error
Error 2
Error 3
Error 4
Error 5
Legend
OFF
Light
Blink
5- SELECTOR SWITCH OPERATION
-Detection method selection
H Manual H Auto
H2 Manual H2 Auto
V Auto
Select the desired method using the detection
method selector switch.
Func.
H
V
H2
SELECTOR
POSITION
FUNCTION
H
It selects Horizontal Detection Area .
H2
It selects Horizontal Detection Area 2.
V
—
-Selection of the area setting method
H Manual H Auto
H2 Manual H2 Auto
V Auto
Select the desired method using the mode
selector switch.
Mode
M
A
SELECTOR
POSITION
FUNCTION
M
Selects the Manual setting.
A
Selects the Auto setting.
-Selecting the Auto mode
H Manual H Auto
H2 Manual H2 Auto
V Auto
Select it using the Auto mode selector switch.
Auto
P
P2
SELECTOR
POSITION
FUNCTION
P
Turns on the Auto Learning.
P2
Turns on the Auto Tracing.
Area A2 alarm output
Area A alarm output
Area B alarm output
Area B2 alarm output
Power selector
switch
Use at “REDWALL”
position.
WALK TESTER <OPM-WT>
REDSCAN
Approximately
30 seconds
(Initialization is
turned on)
Auto mode selection
Detection method selection
Detection area setting button
Operation Indicator
Tamper switch
Mode selection
Detection sensitivity setting (Size.)
Detection sensitivity setting (Sens.)
Offset adjustment
Area A fine alignment
potentiometer
Area B
fine alignment
potentiometer
Area A rough
alignment
Area B rough
alignment