MANUFACTURER'S STATEMENT
MANUFACTURER'S STATEMENT
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise
it may cause electric shock or breakdown of the equipment.
Danger of electric shock.
WARNING
CAUTION
NOTE
Disregard of warning may cause the improper operation causing death or serious injury of
a person.
Special attention is required to the section of this symbol.
Disregard of caution may cause the improper operation causing injury of a person or damage to
objects.
NOTE
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or
death of a person.The meanings of the symbols are as follows.
1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic sliding door.
Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the
installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to
the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which
the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the building
owner/operator on proper operation of the door and the product.
7.The product settings can only be changed by an installer or service engineer. When changed, the
changed settings and the date shall be registered in the maintenance logbook accompanying the door.
The following conditions are not suitable for sensor installation.
-Fog or exhaust emission around the door.
-Wet floor.
-Vibrating header or mounting surface.
-Moving objects or objects that emit light near the detection area.
-Highly reflecting floor or highly reflecting objects around the door.
NOTE
1
CAUTION
Risk of getting caught.
Make sure to affix the mounting template as described in the above chart ,
otherwise it can be dangerous since there may be no detection area around
the threshold. Install the sensor as low as possible on the header.
H : Height from the floor to the bottom of the header
Y : Distance between the bottom of the header and the sensor
X : Distance between the door and the mounting surface
(The mounting height is "H + Y".)
Maximum mounting distance (Y)
X
H
Y
Sensor
Door
Header
Floor
X
6'7" (2.00)
7'7" (2.30)
8'2" (2.50)
9'2" (2.80)
0
No limit
2" (0.05)
8" (0.20)
8" (0.20)
8" (0.20)
4" (0.10)
8" (0.20)
8" (0.20)
8" (0.20)
8" (0.20)
6" (0.15)
5" (0.13)
6" (0.15)
7" (0.19)
8" (0.20)
8" (0.20)
-
5" (0.12)
6" (0.14)
6" (0.15)
10" (0.25)
5" (0.12)
12" (0.30)
-
-
H
8" (0.20)
-
-
-
-
4" (0.11)
[feet,inch (m)]
9'10" (3.00)
0
0
0
0
0
-
1. Affix the mounting template at the desired mounting position.
2. Drill two mounting holes of ø1/8" (ø3.4mm).
3. To pass the cable through the header, drill a wiring hole of ø3/8" (ø10mm).
4. Remove the mounting template.
5. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.
(When setting the detection area close to the door, mount the sensor according to the chart below.)
NOTE
Make sure not to mount the sensor lower than the bottom of header.
WARNING
Danger of electric shock.
Do not use the sensor without the cover.
When using the cable knockout, install the sensor indoors or use the rain-cover
(Separately available) otherwise electric shock or breakdown of
the sensor may occur.
4
Place the housing cover.
If wiring is to be exposed, break the knockout.
Wire the Power & Primary Activation output cable and Secondary Activation output cable to the door controller
properly as shown in the drawing below. The Secondary Activation output requires an input at the door control that
is inhibited(ignored) when the door controller has a safety beam input.If not then install a position / inhibit switch in
series with the blue wire output(see drawing below).
Power &
Primary Activation
output cable
Secondary
Activation
output cable
Activate input
Power supply
Secondary
Activation
output
Power
Inhibit switch status
Primary
Activation
output
Yellow
Grey
AIR-SLIDE 2
Inhibit switch
when door
is closed
Door controller
Blue
Grey
Door controller
without
safety beam input
Door controller
with
safety beam input
2
3
BLUEZONE
When dipswitch 11 is set to ON, the BLUEZONE area, that provides extra safety over the threshold, is activated.
In case the BLUEZONE function is not required, set dipswitch 11 to OFF.
Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 11.
BLUEZONE
(1st row)
2nd row
3rd row
BLUEZONE
(1st row)
2nd row
3rd row
INSTALLATION
1.Plug the connector.
2.Supply power to the sensor. Adjust the detection area and set the dipswitches.
(See
ADJUSTMENTS 4. Dipswitch settings
)
NOTE
Make sure to connect the cable correctly to the door controller before turning the power ON.
When turning the power ON or after adjusting the settings, do not enter the detection area for more
than 10 seconds in order to enable the presence detection.
AIR-SLIDE 2
Knockout
Knockout
Dipswitch 15 can adjust the FLEX EYE function ON or OFF.
- FLEX EYE mode ON.(Dipswitch 15 OFF)
- FLEX EYE mode OFF.(Dipswitch 15 ON)
You can use AIR-SLIDE 2 as normal Autodoor activation sensor.
You do not need to adjust FLEX EYE function.
During FLEX EYE and Secondary Activation area are both working,
Primary Activation output is emited.
When only one function is working, Primary Activation output is not emited.
FLEX EYE MODE
FLEX EYE
Secondary
Activation area
OUTER DIMENSIONS AND PART NAMES
(2) Secondary Activation output Connector
(1) Power & Primary Activation output Connector
(3) Mounting holes
(4) Operation indicator
(8) Secondary Activation area angle adjustment screw
(9) Secondary Activation area width adjustment screws
(5) FLEX EYE Width angle adjustment screw
(6) FLEX EYE Depth angle adjustment screw
(7) Dipswitches
(10) Detection window
(11) Area adjustment tool
[inch (mm)]
Touchless plate
9 10/16” (245)
1 7/16” (37)
5/16”
(7.5)
2 11/16”
(68)
1 7/16” (36)
1 11/16” (43)
4 15/16” (125)
4” (102)
4” (102)
(1)
(2)
(3)
(4)
(9)
(8)
(5)
(6)
(7)
(10)
(11)
This sensor is designed to detect a hand approaching to a touchless plate as a knowing act activation device.
Please make sure to understand the following working principle.
This sensor sends primary activation output when both "FLEX EYE and 2nd to 4th row" detect some object.
After the detection until the door fully closes, 2nd to 6th rows work as a Secondary Activation output.
"FLEX EYE" means a detection area for the hand.
Secondary Activation area is from the 2nd row to the 6th row.
BLUEZONE
(1st row)
2nd row
3rd row
4th row
5th row
6th row
FLEX EYE
1
2
3
4
5
6
FLEX EYE
1
2
3
4
5
6
FLEX EYE
WORKING PRINCIPLE
Model
Cover color
Mounting height
Detection area
Detection method
FLEX EYE
angle adjustment
Power supply
Power consumption
Operation indicator
Primary, Secondary
Activation output
: AIR-SLIDE 2
: Black
: 6'7"(2.0m) to 9'10"(3.0m)
: See
DETECTION AREA
: Active infrared reflection(*1)
: Depth : -14° to +2°
Width : ±42° ( 7 clicks with 6°every
one click-Reft/Light )
: < 2.0W (< 3VA at AC)
: See
Operation indicator table
Output hold time
Operating temperature
Operating humidity
IP rate
Weight
Accessories
: Approx. 0.5 sec.
Response time
: < 0.3 sec.
: -4 to 131°F (-20 to +55°C)
: <80%
: IP44
: 8.8oz (250g)
: 1 Operation manual
2 Mounting screws
1 Mounting template
The specifications herein are subject to change without prior notice due to improvements.
NOTE
*1 : BLUEZONE (1st row), 2nd and 3rd rows have a presence detection function.
*2 : See
BLUEZONE
*3 : See
FLEX EYE MODE
SPECIFICATIONS
1 Area adjustment tool
1 Power & Primary Activation
output cable 8'2" (2.5m)
1 Secondary Activation output
cable 8'2" (2.5m)
Secondary
Activation area
angle adjustment
Width : ±7° ( 2 clicks with 3.5°every
one click-Reft/Light )
: Depth : -16° to +0°
: Form A relay
50V 0.3A Max. (Resistance load)
: 12 to 24V AC ±10% (50/60Hz)
12 to 30V DC ±10%
Operation indicator table
1sec.
1sec.
Status
Stand-by (Operation mode)
Set-up
BLUEZONE (1st row) detection (*2)
2nd row detection
3rd row detection
4th-6th row detection
Operation indicator color
Yellow Blinking
Green
Blue
Red Blinking
Red
Orange
Signal saturation(Secondary Activation area)
Signal saturation (FLEX EYE)
Sensor failure
Slow Green Blinking
Slow Purple Blinking
Fast Green Blinking
Stand-by (Installation mode)
Yellow
FLEX EYE detection (*3)
FLEX EYE & 2nd-4th row detection
Fast Purple Blinking
Purple
B
C
D
E
F
G
H
I
J
BLUEZONE
(1st row)
2nd row
3rd row
4th row
5th row
6th row
FLEX EYE
A
DETECTION AREA
The actual Secondary Activation area may become smaller depending on the ambient light, the color /
material of the object or the floor as well as the entry speed of the object.
The sensor may not be activated when the entering speed of the object or a person is slower than
50mm / sec. or faster than 1500mm / sec.
NOTE
B
C
D
E
F
G
H
I
J
A
[ feet,inch (m) ]
6’7” (2.00)
7’7” (2.30)
8’2” (2.50)
9’10”(3.00)
1’8” (0.45) 1’8” (0.52) 1’10” (0.56)
2’3”(0.68)
7’5” (2.26) 8’6” (2.60) 9’3” (2.82) 11’1”(3.39)
5’8” (1.72) 6’6” (1.98) 7’11” (2.15)
8’6”(2.59)
3’5” (1.04) 3’11” (1.20) 4’8” (1.43)
5’1”(1.56)
6’7” (2.00) 7’7” (2.30) 8’2” (2.50) 9’11”(3.01)
5’ (1.53) 5’9” (1.76) 6’4” (1.92)
7’7”(2.30)
3’7” (1.09) 4’1” (1.25) 4’6” (1.36)
5’4”(1.63)
2’7” (0.80)
3’ (0.92) 3’4” (1.01) 3’12”(1.21)
8” (0.20)
9” (0.23)
10” (0.26)
1’(0.31)
Charts show the values in the following
Secondary Activation area angle
adjustment settings ;
Depth :0°
Width :0°
Secondary
Activation
output
Power
Primary
Activation
output
AIR-SLIDE 2
: Emitting spots
: Emitting spots
(can be eliminated)