-7-
Dip switch
2
8-B
PULSE COUNT
ON
(factory default)
POSITION
FUNCTION
OFF
The LED lights when someone is detected.
The LED does not light even if someone is
detected
ON
OFF
2 times
(factory default)
POSITION
FUNCTION
3 times
Suitable for standard applications.
Set this when used in a location with drastic
temperature fluctuation or
hostile environment.
3 times
2 times
Dip switch
1
8-A
LED ON/OFF
HX-40
HX-40AM
HX-40
HX-40AM
FUNCTION SETTING
8
Dip SW
1 LED ON/OFF SELECTOR
2 PULSE COUNT SELECTOR
3 EXTERNAL SENSOR INPUT SELECTOR
4 TROUBLE OUTPUT SELECTOR
ANTI-MASKING
SENSITIVITY
SELECTOR (8-F)
PIR SENSITIVITY SELECTOR
(8-A)
(8-B)
(8-C)
(8-D)
(8-E)
Do not touch
NOTE: For the walk test, move more than 1 m (0.3 ft.) away from
the detector.
AND
(factory default)
POSITION
FUNCTION
OR
When both the Main unit and the satellite detect
someone, the alarm is output.
Set to this when not connecting a satellite unit.
Note: The alarm is not output unless both the Main
unit and the satellite detect someone within
60 seconds.
When either the Main unit or the satellite detects
someone, the alarm is output.
OR
AND
By connecting a satellite unit (another warning sensor), you can
expand the detection area and correct false alarms.
As a satellite unit, you can use any general no-voltage contact
output (NC) warning sensor, including the following.
<Infrared (AIR) sensors, thermal line (PIR) sensors, magnet
switches, etc.>
Dip switch
3
8-C
EXTERNAL SENSOR INPUT
HX-40
HX-40AM