background image

-4-

In

In

Out

Out

Wiring sponge pad

1

2

3

4

Push the shaft cover clip outwards to
remove the cover.

Loosen the adjustment screw, tilt the
bracket about 45° and pass through the
wire.

Fasten the bracket to the wall.
Change the bracket direction according
to whether the Main unit is to face left
or right.

Pass the wire through the base
knockout and install the base on the
bracket.

Adjustment
screw

BRACKET INSTALLATION AND ADJUSTMENT

6

20°

20°

90°

90°

6-A

Bracket installation

Shaft cover

Push

Using the bracket makes it possible to adjust

the unit through 180° degree.

In cases where the ground is uneven and therefore not parallel with the base of the unit, it is
possible to adjust the unit vertically by +/- 20 degree (see section 6-B)

Do not change the detection
distance with bracket.
Use the masking seal to
adjust the detection distance.

Caution>>

Summary of Contents for HX-40/40AM

Page 1: ...h two PIRs HX 40AM HX 40 with IR anti masking feature HX 40 40AM HX 40 40AM Warning Warning Caution INSTALLATION HINTS 1 1 INSTALLATION HINTS 1 2 PARTS IDENTIFICATION 2 3 KNOCKOUTS 2 4 DETECTION AREA...

Page 2: ...masking infrared LED HX 40AM only For wall fastening Wiring Hole Wiring Hole Off the shelf magnet switch installation position Adjustment screw For switch box fastening For main unit fastening Up dow...

Page 3: ...DETECTION AREA SETTING 4 4 B Detection Length Adjustment 4 A Detection Area Top view of detection area 90 4 0 3 0 2 0 10 0 8 m 26 7ft 8 m 26 7ft 12 m 40 ft 12 m 40 ft 3 0 m 10 ft 12 m 40 ft 2 5 m 8 3...

Page 4: ...ugh the base knockout and install the base on the bracket Adjustment screw BRACKET INSTALLATION AND ADJUSTMENT 6 20 20 90 90 6 A Bracket installation Shaft cover Push Using the bracket makes it possib...

Page 5: ...astened to the bracket you can not remove the shaft cover Caution 9 6 B Detection distance check and up down angle adjustment Adjustment screw The LED lights when you come closer within 9 m 30 ft Adju...

Page 6: ...NC COM NO SP SP AUX INPUT ALARM POWER 9 5 18VDC WIRING 7 1 TAMPER terminals to be connected to a 24 hour supervisory loop HX 40AM HX 40 SPARE Non short ALARM OUTPUT N O ALARM OUTPUT COM ALARM OUTPUT N...

Page 7: ...OR 8 A 8 B 8 C 8 D 8 E Do not touch NOTE For the walk test move more than 1 m 0 3 ft away from the detector AND factory default POSITION FUNCTION OR When both the Main unit and the satellite detect so...

Page 8: ...anti masking signal When an object is placed close to the lens surface for a period of more than 180 seconds the IR Anti Masking circuit will activate and generate a trouble signal LED Operation DETE...

Page 9: ...etween the moving object and the background For example when the detection distance is set to 12 m 40 ft sometimes vehicles 13 m 43 ft away may be detected In this case set the detection distance to 9...

Page 10: ...1 2 3 4 5 6 7 8 9 0 1 9 2 8 3 7 4 6 5 56 HX 40AM HX 40 LED FUNCTIONS 10 DETECTOR STATUS Alarm Warm up period LED Indication Red light Red blinks LED operation Light Blink OFF Red DETECTOR STATUS Alarm...

Page 11: ...height Bracket adjust angle Weight Accessories HX 40 HX 40 AM Passive infrared 12 m 40 ft 85 wide 94 zones 4 m 5 5 m 9 m 12 m 13 ft 18 ft 30 ft 40 ft 0 3 1 5 m s 1 5 ft s 2 0 C 3 6 F at 0 6 m s 9 5 1...

Page 12: ...www optexamerica com OPTEX KOREA CO LTD KOREA TEL 82 2 719 5971 URL http www optexkorea com OPTEX SECURITY Sp z o o POLAND TEL 48 22 598 06 55 URL http www optex com pl OPTEX DONGGUAN CO LTD SHENZHEN...

Reviews: