background image

The Extension terminal may be useful for the following situation. 

  If the Door Contact cannot be mounted on the door frame, you can connect an additional extension switch to the extension terminal to mount the 

Door Contact remotely. 

  Any dry contact device with N.C. (Normal Close) loop can be connected to the Extension Terminal making the Door Contact serve as an Universal 

Transmitter. 

  Multiple dry contact device can be wired together with Door Contact, as show in diagram below. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

N

N

O

O

T

T

E

E

>

>

>

>

 

 

  If both the Internal Magnet Switch and Extension Terminal operate together, then 

  When  the  protected  door  is  opened/closed 

or

  the  external  device  is  triggered,  the  Door  Contact  activates  and  transmits  a  signal 

immediately . 

  However, the Door contact will only transmit a 

Door Closed

 or 

Restored

 signal after both the door 

and

 the external device are restored for 

3 sec. 

 

10  SPECIFICATIONS 

 

Model 

GEN-DC 

Frequency 

433.82 MHz 

Power source 

CR2 Lithium battery 

Battery life 

Approx. 6 years (20 activations per day, 25°C) 

Operating conditions 

-10°C to +45°C (up to 85% non-condensing) 

Weight 

50 g (including battery) 

 

11 

DIMENSIONS

 

 

32 

1

08

 

21 

16.7 

12 

10.5 

9

2.

33

.5

 

4

5.

Unit: mm

 