40
Installer logout
When finish all settings, click the button of “Installer Logout”.
When logged out, and the background of the screen becomes gray, and the three buttons will be
disappeared.
3-4 Operation checking
Table 3-2
Output
Condition
Indicator LED
Control Box(A3001CB)
TOF Sensor(A3001S)
Stand by
Waiting a start signal
Green
continuously
Green
continuously
Zero
Start signal & 2 sec later
No one in interlock
Blue
0.2 sec
Blue
0.2 sec
One
Start signal & 2 sec later
One person in interlock
Blue
2 sec
Blue
2 sec
More
Start signal & 2 sec later
Two or more persons in interlock
Red
2 sec
Red
2 sec
Suspicious
Start signal & 2 sec later
Masking against TOF Sensor
Blue & Red
2 sec
Blue & Red
2 sec
AIR
Something or someone in interlock
Green
Blink at 2 Hz
Green
Blink at 2 Hz
After mounting and setting have been made, check the operations as described in Table 3-2.
Each operating condition is described in Table 3-2.
Check the output seeing Indicator LED.
The start signal is generated by the entry door, once the door has been opened and closed.
2 seconds later the output signal is generated.
Then the output states can be checked.