11
2 Mounting and wiring
2-1 Mounting TOF sensor
Mounting position of TOF Sensor
The mounting position of TOF Sensor changes by a use (One way or Two way) and size of interlock area as
shown as below;
For One way
Interlock area within 1.5 m
×
1.0 m (W
×
D)
Fig 2-1
Table 2-1
Mounting height
2.3 m
2.6 m
2.9 m
A
1.0 m max.
B
1.5 m max.
1.9 m max.
2.3 m max.
C
0.3 to 0.5 m
0.4 to 0.6 m
0.5 to 0.7 m
D
C + 0.5 m max.
C + 0.6 m max.
C + 0.7 m max.
[Secured area]
[Public area]
A
Entry
B
D
C
Authorizati
on device
for entry
Center ±0.1 m
TOF Sensor
direction