CONTENT 

1. 

PACKAGING ............................................................................................................................................................... 2 

2. 

BASIC DESCRIPTION .................................................................................................................................................. 2 

3. 

TECHNICAL SPECIFICATION ....................................................................................................................................... 2 

4. 

SAFETY REQUAREMENTS .......................................................................................................................................... 2 

5. 

CONNECTION AND COMMUNICATION ..................................................................................................................... 3 

6. 

OPERATION MODES .................................................................................................................................................. 3 

6.1. 

Equithermal mode ............................................................................................................................................ 3 

6.2. 

Modulation mode ............................................................................................................................................. 4 

7. 

INSTALATION EXAMPLE ............................................................................................................................................ 4 

8. 

WARRANTY ................................................................................................................................................................ 5 

 

 

 

 

 

Summary of Contents for Biopel CS-503

Page 1: ...ned off one by one to reduce heat production when not needed Cascade controller decreases fuel consumption extends cleaning intervals for not running boilers and makes whole hydraulic system more effi...

Page 2: ...GING 2 2 BASIC DESCRIPTION 2 3 TECHNICAL SPECIFICATION 2 4 SAFETY REQUAREMENTS 2 5 CONNECTION AND COMMUNICATION 3 6 OPERATION MODES 3 6 1 Equithermal mode 3 6 2 Modulation mode 4 7 INSTALATION EXAMPLE...

Page 3: ...current 250mA CS 503 diameters o Height 20mm o Length 100mm o Depth 40mm RS connection cable o Length 5m o Connector RS Max operational temp 20 to 45 C Package weight 35g 4 SAFETY REQUAREMENTS Read th...

Page 4: ...ings and open Cascade control submenu Following chapter is describing main functions inside this submenu Read it carefully and then proceed to Installation examples chapter for examples of exact insta...

Page 5: ...r settings v8 or Main settings v9 Cascade Lower limit of effectivity Next boiler will be deactivated after 20min from time when boiler before was deactivated This process is repeated until CH boiler t...

Page 6: ...y materials faulty design faulty design or removed as soon as at our expense provided that the device it is in normal condition according to the Instruction manual is not damaged mechanically no unaut...