Opop Biopel CS-503 Quick Start Manual Download Page 3

 

1.

 

PACKAGING 

Following list of parts is included inside CS-503 
package: 

1.

 

CS-503 cascade controller 

2.

 

4 pcs of RS connection cable (5m) 

3.

 

230V power supply cord 

4.

 

User manual 

2.

 

BASIC DESCRIPTION 

1.

 

CS-503 controller 

2.

 

4pcs of RS connectors, 
for  connection  of  each  boiler  enabling  multi-
structural communication provided by cascade 
controller.  

3.

 

Indication diodes,  
which  indicates  real  time  boiler  operation. 
Light  indicates  that  boiler  is  in  operation,  no 
light  indicates  that  boiler  is  turned  off  by 
cascade controller.  

4.

 

Power supply cord,  
to connect controller to the electricity.  

 

 

 
 

 

 

 

       Main box 

 
 

 

 

 

       Indication diodes 

 

 

 

 

       No light – boiler off 

 

 

 

 

       Light – boiler on 

 

 

 

RS outputs for boiler connection 

Power supply cable 

 
CS-503  cascade  controller should  be  connected close 
to the boilers to connect each of them with 5m RS cable 
supplied in standard delivery.  
Position  all  cables  in  a  way  to  protect  them  against 
physical and heat damage.  
Device  should  not  be  installed  close  to  other 
electromagnetic  devices  such  as  motors,  fans  of  the 
boiler. Safe distance is at least 50cm.  
 
 
 

3.

 

TECHNICAL SPECIFICATION 

Following list is specification of basic electrical and 
other technical values.  

 

Power supply   

 

230V 

 

Power consumption 

 

1W 

 

Maximal current 

 

250mA 

 

CS-503 diameters: 

o

 

Height   

 

20mm 

o

 

Length   

 

100mm 

o

 

Depth   

 

40mm 

 

RS connection cable: 

o

 

Length   

 

5m 

o

 

Connector 

 

RS 

 

Max operational temp.   

-20 to 45°C  

 

Package weight  

 

35g 

 

4.

 

SAFETY REQUAREMENTS 

Read these instructions carefully to make sure CS-503 
will work without any problem in all conditions.  

 

Do  not  install  any  kind  of  cascade  controller 
equipment  directly  on  boiler  or  boiler 
equipment  surface  to  protect  device  and 
cables against high temperatures.  

 

Cables  connecting  each  boiler  should  be 
covered  and  positioned  in  a  safe  way,  so  no 
heat ash or dust will damage them in long term 
use.  

 

Prevent 

installation 

of 

electronical 

components  in  boiler  rooms  with  high 
humidity.  

 

CS-503  cascade  controller  shouldn’t  be 
installed  close  to  any  kind  of  wireless  or 
electromagnetically  operated  device.  Safe 
distance is 50cm or more.   

 

Update  boiler  control  unit  to  the  latest 
firmware  version  to  make  sure  cascade 
operation is included in controller’s submenu.  

 

Communicate the exact way of operation with 
your  installer  to  be  sure  cascade  controller 
operates  all  boilers  in  a  way  you  need. 
Consider  both  possible  operations  with  CH 
boiler  temperature  sensor  and  outside 
Weather sensor.  

 

Weather  sensor  is  included  in  431N  module 
packaging which is part of each burner box. To 
make  weather  cascade  operation  work,  also 
431N module must be installed into the boiler 
connected  in  1

st

  RS  output  of  cascade 

controller.  

 

Summary of Contents for Biopel CS-503

Page 1: ...ned off one by one to reduce heat production when not needed Cascade controller decreases fuel consumption extends cleaning intervals for not running boilers and makes whole hydraulic system more effi...

Page 2: ...GING 2 2 BASIC DESCRIPTION 2 3 TECHNICAL SPECIFICATION 2 4 SAFETY REQUAREMENTS 2 5 CONNECTION AND COMMUNICATION 3 6 OPERATION MODES 3 6 1 Equithermal mode 3 6 2 Modulation mode 4 7 INSTALATION EXAMPLE...

Page 3: ...current 250mA CS 503 diameters o Height 20mm o Length 100mm o Depth 40mm RS connection cable o Length 5m o Connector RS Max operational temp 20 to 45 C Package weight 35g 4 SAFETY REQUAREMENTS Read th...

Page 4: ...ings and open Cascade control submenu Following chapter is describing main functions inside this submenu Read it carefully and then proceed to Installation examples chapter for examples of exact insta...

Page 5: ...r settings v8 or Main settings v9 Cascade Lower limit of effectivity Next boiler will be deactivated after 20min from time when boiler before was deactivated This process is repeated until CH boiler t...

Page 6: ...y materials faulty design faulty design or removed as soon as at our expense provided that the device it is in normal condition according to the Instruction manual is not damaged mechanically no unaut...

Page 7: ...Vala sk Mezi Bank details Komer n banka a s account no 1608851 0100 Reg no 47674105 VAT no CZ 47674105 Phone Sales Dept 571 675 589 Secretariat 571 611 250 Production 571 675 405 Sourcing 571 675 114...

Reviews: