SWG-1016 User Manual
21
OpenVox Communication Co. ,LTD.
URL: www.openvox.cn
The same algorithm with single time limitation, the total calling time of this port can’t beyond the product
of “Step” and “Call Duration Limitation”.
If the duration of a call is less than “Minimum Charging Time”, it will be not included in “Call Duration”.
You can set a digit for “Alarm Threshold”, when the call minutes less than this value, the gateway will
send alarm info to designated phone.
You can enable your Auto Reset, then choose by day, by week, or by month.
Figure 3-7 Auto Reset Settings
Table 3-2
Description of Call Duration Limit Settings
Options
Definition
Step
Step length value range is 1-999s, step length multiplied by time of
single call just said a single call duration time allowed.
Enable Single Call
Duration Limit
Definite maximum call duration for single call. Example: if Time of
single call set to 10, the call will be disconnected after talking
10*step seconds.
Enable Call Duration
Limitation
This function is to limit the total call duration of CDMA channel.
The max call duration is between 1 to 999999 minutes.
Minimum Charging
Time
A single call over this time, CDMA side of the operators began to
collect fees, unit for seconds.
Alarm Threshold
Define a threshold value of call minutes, while the call minutes
less than this value, the gateway will send alarm information to
designated phone.
Alarm Description
Alarm port information description, which will be sent to user