background image

Ë µ

à÷

Ê é

Ë µ

à÷

Ê é

R

KEC-30

KEC-30

ELECTRONIC  FLUXGATE  COMPASS

OPERATOR`S MANUAL

Summary of Contents for KEC-30

Page 1: ...R KEC 30 KEC 30 ELECTRONIC FLUXGATE COMPASS OPERATOR S MANUAL...

Page 2: ......

Page 3: ...12 1 5 4 Heading Alignment Setting 12 1 5 5 Language Setting 13 1 5 6 Time Setting 13 1 5 7 Output Setting 14 FOREWORD 1 2 INSTALLATION MOUNTING CONSIDERATIONS 16 2 1 Fluxgate Compass Unit 16 2 1 1 16...

Page 4: ...HOOTING 23 3 1 Preventive maintenance 23 3 2 Troubleshooting 24 INTERCONNECTION DIAGRAM 27 DISPLAY UNIT SIZE 29 FLUXGATE SENSOR SIZE 30 CONNECTING CABLES 28 C BRACKET SIZE CHART 31 THE SPECIFICATIONS...

Page 5: ...55 for the display unit Use of the equipment out of those ranges may damage the equipment Safety Instructions for the Operator Safety Instructions for the Installer WARNING Do not open the cover unle...

Page 6: ...ne environment However no machine can perform its intended function unless properly installed and maintained Please carefully read and follow the operation installation and maintenance procedures set...

Page 7: ...A AIS ECDIS scanning sonar There are no mechanical parts such as gimbals or rotating motor thus the compass is free from routine maintenance Chinese and English menu display Electronic Fluxgate Compas...

Page 8: ...ON The KEC 30 consists of a Display unit and a Fluxgate Sensor unit Fluxgate Sensor unit KFG 25 Display unit KEC 30 External GPS data input The heading signal output DC10 5V 40V KEC 30 ELECTRONIC COMP...

Page 9: ...ct the menu item ENT To identify or modify the selection KEC 30 ELECTRONIC COMPASS MENU PWR KEC 30 ENT ESC DIM DISP DIM Adjust LCD brightness and contrast DISP Select the display mode PWR To switch on...

Page 10: ...l illumination 3 Press or to adjust 4 Press the ESC key LCD display contrast to confirm and exit 1 2 Turning the power on off Turning the Power On press PWR once to switch on the unit with a beep soun...

Page 11: ...SP key to cycle 6 210 240 W 300 330 N 30 N 60 E 120 150 S HDT 224 SOG COG N 22 45 108 E 115 47 203 211 0 4Kt 224 220 230 240 250 260 COG kt HDT 200 210 SOG 0 4 3D 2011 01 31 03 36 211 HDT COG SOG kt N...

Page 12: ...displaying all other navigation data magnetic heading Date Course Over Ground Position data Speed Over Ground Location Status Time Boat s heading HDT COG SOG kt N 22 45 108 E 115 47 203 224 No extern...

Page 13: ...Steering display The steering display shows heading in digital and analog form SOG and COG are also indicated Azimuth Scale Heading tag 8 224 220 230 240 250 260 COG kt HDT 200 210 SOG 210 240 W 300 3...

Page 14: ...ta contain Lon Lat information KEC30 would use it to calculate Magnetic Variation to show HDT direction otherwise show HDG direction Choose when MAGNETIC whether Input any voyage data Are show HDG 9 M...

Page 15: ...poorly the calibration procedure will adjust compass characteristics to compensate The calibration should only be done if the compass is known to be inaccurate If the KEC 30 display as constant offse...

Page 16: ...er second update 210 240 W 300 330 N 30 N 60 E 120 150 S HDG 224 SOG COG Auto heading adjustment failed 11 210 240 W 300 330 N 30 N 60 E 120 150 S HDG 224 SOG COG Auto heading adjusting 0 4 kt 211 210...

Page 17: ...s and electronic fluxgate compass Cancel ESC OK ENT MANUAL HEADING ADJUST 120 00 150 00 180 00 210 00 240 00 270 00 300 00 330 00 0 00 30 00 60 00 90 00 1 5 4 Heading Alignment Setting Adjustment of h...

Page 18: ...ME SETTING to enter the corresponding time difference select TIME SETTING 2 Press or key to move the cursor 3 Press or key to modify the 4 Press ENT key Note If the change successful The UTC in the to...

Page 19: ...000ms 1s The standard interval is 200ms three can output together c 48 The optional speed of output the standard is 00 the optional one is 9600 19200 and 38400 1000 4800 9600 19200 38400 25 100 200 1...

Page 20: ...efault setting or press ESC to quit without any change Note When you select to load factory default setting all saved settings would be cleared This action can not reversible FACTORY DEFAULT Restore t...

Page 21: ...for iron and steel or other magnetic materials use not magnetic screws for fixed the unit Select the vertical way of positions for installation Please installed the Magnetic field sensor Steel vessel...

Page 22: ...mounting To ensure the signal of sailing directions is accuracy please choose a location where vibration and shock are minimal only suitable for fiberglass or wooden vessel Installed in the surface o...

Page 23: ...save the space The bulkhead cannot contain the steel with magnetic interference material Only suitable for fiberglass or wooden vessel Deck head Bracket Fluxgate Sensor Top Mount Bulkhead Side Mount...

Page 24: ...the unit away from air conditioner vents Keep the unit out of direct sunlight because of heat that can build up inside their cabinets Choose a well ventilated location Choose a location where it can...

Page 25: ...g dimensions 2 Screw the knobs into the display unit 3 Set display unit to the hanger and tighten the knobs 4 Run the ground wire between the ground terminal on the display unit and the ship s superst...

Page 26: ...ssories The list below Name 2 M4X30 M4 M6X12 M6 4 4 2 2 Type Qty Flush Mount Fixture Wing Bolt Wing Nut Hex Bolt Spring Washer Manufacturing 3 Fasten the cosmetic panel to the display unit with hex bo...

Page 27: ...signal equipment The power source for the compass display shall be provided by the independent fuse in radio interference should Magnetic field sensors connected Power data cable connection 6mm 1 5M...

Page 28: ...necessary Check for water leakage in the Clean or replace as necessary Remove dust and dirt from the display unit and unit with a dry soft cloth For the LCD wipe it carefully to prevent scratching usi...

Page 29: ...nician check the fuse Heading indication changes randomly when ship is at anchor or does not change when ship moves Sensor trouble Run the diagnostic test to determine cause Cause Remedy Heading outpu...

Page 30: ...SA Input connector is TTL RS 232 RS 422 Input data contains RMC GSA 3 2 OUTPUT 1 NMEA0183 HDG HDT HDM a Output data includes the following three HDT True heading HDM Magnetic heading HDG Magnetic head...

Page 31: ...2 0 IEC standard digital interfaces part 1 6 DISPLAY 6 1 4 5 diagonal 95 W 63 H mm LCD 240 160 pixels 4 ENVIRONMENTAL CONDITIONS 4 1 Ambient Temperature Display Unit 15 C to 55 C unit 25 C to 70 C Flu...

Page 32: ...Echo sounder 27 Fluxgate Sensor Bracket 1 0 M s t a n d a r d Display Radar Plotter Ect INTERCONNECTION DIAGRAM...

Page 33: ...nput White Input Blue Output Yellow Output Green NC GND Power Red Power Black POWER DATA I O GND 1 2 3 4 5 6 Green Red Yellow White blue Shield 28 1 2 3 4 6 5 7 8 1 2 3 4 5 6 To fluxgate Sensor Unit C...

Page 34: ...15 85 7 211 7 140 2 10 05 31 5 168 9 175 0 211 7 130 7 104 6 KEC 30 ELECTRONIC COMPASS 29 DISPLAY UNIT SIZE...

Page 35: ...212mm 37mm 103mm 95mm 25 3mm 67 8mm 42 2mm 6 1mm 30 FLUXGATE SENSOR SIZE...

Page 36: ...31 104mm 4 5mm 104mm 97mm 31mm C BRACKET SIZE CHART...

Page 37: ......

Reviews: