2. INSTALLATION & MOUNTING CONSIDERATIONS
2. INSTALLATION & MOUNTING CONSIDERATIONS
2.1 Fluxgate
Unit
2.1.1 Outdoor installation
Keep the length of the cable in mind when selecting a mounting location.
It should be far away from their minimum 1 meters to prevent the
influence for iron and steel or other magnetic materials.
use not magnetic screws for fixed the
unit.
Select the vertical way of positions for installation.
Please installed the Magnetic field sensor
Steel vessel,
distortion
can be minimized.
Sensor
fluxgate sensor
on the top of wheelhouse
Don't install it in a room so that the magnetic
16
Cable to display unit
Fluxgate Sensor
Threaded tubes
(At least one meter length)
Rope
Fixed screw
Mast
Radar antenna
Wheelhouse
Fluxgate Sensor