background image

HOBO® RX3000 Remote Monitoring Station Manual 

18255-L 

The HOBO RX3000 Remote Monitoring Station provides continuous logging for a broad range of 
energy and weather monitoring applications with up to ten smart sensors, optional analog sensor 
and relay modules, and wireless sensor motes. Data from the RX3000 station is transferred at 
regular connection intervals to HOBOlink® web-based software where you can check the latest 
conditions, view graphs, configure sensors and alarms, set up a dashboard, download your data, 
or schedule data delivery via email or FTP. Inside its weatherproof enclosure, this durable station 
has a built-in LCD screen to check the current system configuration and status, start and stop 
logging, add and remove smart sensors, and connect to HOBOlink on demand. Up to three 
individual relays can be activated on the optional relay module while the optional analog module 
has four analog inputs that support excitation power, scaling, and statistics measurements. An 
optional RXW Manager module is also available for the station to set up the HOBOnet Wireless 
Sensor Network, which can support up to 50 motes. All three easy-to-install modules can be 
configured with HOBOlink. 

Specifications 

Station 

 

Operating Range 

-40° to 60°C (-40° to 140°F); no remote communications for battery 
voltage less than 3.9 V DC 

Smart Sensor Connectors 

10 

Smart Sensor Network Cable 
Length 

100 m (328 ft) maximum 

Smart Sensor Data Channels 

Maximum of 15 (some smart sensors use more than one data 
channel; see sensor manual for details) 

Module Slots 

Logging Rate 

1 second (RX3001 and RX3002) or 1 minute (RX3003 and RX3004) to 
18 hours 

Time Accuracy 

±8 seconds per month in 0° to 40°C (32°F to 104°F) range;  
±30 seconds per month in -40° to 60°C (-40° to 140°F) range 

Battery Type/Power Source 

4 Volt, 10 AHr, rechargeable sealed lead-acid; external power 
required using one of these options: AC power adapter (AC-U30), 
solar panel (SOLAR-xW), or external power source 5 V DC to 17 V DC 
with external DC power cable (CABLE-RX-PWR) 

Rechargeable Battery  
Service Life 

Typical 3–5 years when operated in the temperature range -20° to 
40°C (-4°F to 104°F); operation outside this range will reduce the 
battery service life 

Memory 

32 MB, 2 million measurements, continuous logging 

Alarm Notification Latency 

Logging interval plus 2–4 minutes, typical 

Enclosure Access 

Hinged door secured by two latches with eyelets for use with user-
supplied padlocks 

LCD 

LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react 
slowly or go blank in temperatures outside this range 

Materials 

Outer enclosure: Polycarbonate/PBT blend with stainless steel hinge 
pins and brass inserts; Inner enclosure: Polycarbonate; Gaskets: 
Silicone rubber; Cable channel: EPDM rubber; Cable opening cover: 
Aluminum with ABS plastic thumb screws; U-Bolts: Steel with zinc 
dichromate finish 

Size 

18.6 x 18.1 x 11.8 cm (7.3 x 7.1 x 4.7 in.); see diagrams on next page 

Weight 

2.2 kg (4.85 lb) 

Mounting 

3.8 cm (1.5 inch) mast or wall mount 

Environmental Rating 

Weatherproof enclosure, NEMA 4X (requires proper installation of 
cable channel system) 

 

HOBO RX3000 Remote 
Monitoring Station 

Models:  RX3001-00-01 Ethernet 

RX3002-00-01 Wi-Fi 
RX3003-00-01 Cellular 
RX3004-00-01 Cellular 4G 

Included Items: 

 

Two plates for cable access 
openings with eight 
thumbscrews and one wrench 

 

Two rubber cable channels 

 

Rubber plugs 

 

Grease packet 

 

Two mounting plates with 
four screws 

 

Grounding wire 

 

Two U-bolts 

Required Items: 

 

HOBOlink 

 

HOBOware

®

 3.7.2 or later 

with USB cable for RX3002 Wi-
Fi models (optional for 
RX3001, RX3003, and RX3004 
models) 

 

AC adapter (AC-U30) or solar 
panel (SOLAR-xW) 

Optional Items: 

 

Smart sensors 

 

Analog sensor module 
(RXMOD-A1) 

 

Relay module (RXMOD-R1) 

 

RXW Manager (RXMOD-RXW-
xxx) and RXW motes 

 

External DC power cable 
(CABLE-RX-PWR) 

 

Tripod kit (M-TPA or M-TPB) 

 

Guy wire kit (M-GWA) 

 

1/2 inch stake kit (M-SKA) 

 

Grounding kit (M-GKA), 
required if using wind speed 
or wind direction smart sensor 

 

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for HOBO RX3000 Series

Page 1: ...ns AC power adapter AC U30 solar panel SOLAR xW or external power source 5 V DC to 17 V DC with external DC power cable CABLE RX PWR Rechargeable Battery Service Life Typical 3 5 years when operated i...

Page 2: ...dBm for 1 0 Mbps Cellular RX3003 and RX3004 Wireless Radio RX3003 GSM GPRS EDGE Quad band 850 900 1800 1900 MHz UMTS HSPA Five band 800 850 900 1900 2100 MHz RX3004 GSM GPRS EDGE Quad band 850 900 180...

Page 3: ...s product as complying with all relevant directives in the European Union EU RXMOD RXW 922 See last page Table of Contents Device Components and Operation 4 LCD Operation 5 Setting up the Station 7 a...

Page 4: ...ation Charging Port Use this port to plug in an AC adapter solar panel or external power source to keep the battery charged see Setting up the Station and Battery Information USB Port Use this port to...

Page 5: ...dicates the last connection to HOBOlink was ok indicates there was a problem with the last connection check the Connections log in HOBOlink Smart Sensor and Module Status This part of the LCD shows th...

Page 6: ...losed c In this example the first and third relays are open and the second one is closed This will blink in the lower right part of the LCD when a firmware update is underway It will display which mod...

Page 7: ...er module on the left and the relay module on the right for easier cable routing c Using a Phillips head screwdriver tighten the screw at the bottom of each module In this example an analog module is...

Page 8: ...eckbox f Enter the IP Address Subnet Mask Gateway and DNS Server Consult your Network Administrator for the appropriate addresses to complete these fields g Click Save in the RX3000 Manager Click Done...

Page 9: ...or one smart sensor through the larger of the two cable openings and plug it into one of the 10 smart sensor connectors Repeat for any additional smart sensors b Press the Select button to view the sm...

Page 10: ...ion 4 GND EX RTN 4 GND EX RTN 5 CH2 SIGNAL 5 CH4 SIGNAL 6 CH2 GND 6 CH4 GND 7 SHIELD 7 SHIELD Note All four input channels share the same common ground Analog Module Functional Diagram To connect rela...

Page 11: ...section on your station s page in HOBOlink c Click Save or click Next Smart Sensors Logging and Configuration You can configure both the global settings that affect all smart sensors logging interval...

Page 12: ...he sensor measurement type for that mote g Click one of the mote measurement types from menu under Module Wireless Sensors Logging as shown in the following example h Type a label for the measurement...

Page 13: ...he four analog sensor channels from the menu such as Channel 1 shown in this example g Select Enable Graph if you want the sensor data to be graphed in HOBOlink h Select Enable this channel if you wan...

Page 14: ...ired 4 Under Select Data to Export choose the name of the custom data export you want to be delivered or follow the previous set of steps to set up a custom data export 5 Under Data Destination select...

Page 15: ...ps send an email or text or close open or pulse one of the three relays if a relay module is installed For email or text enter the details and then select Send on Clear Also if you want an email or te...

Page 16: ...is inserted through the bottom of the station case Do not reconnect the power on the station until the mote is plugged in as shown 7 Plug in the battery and charging device and wait for the device to...

Page 17: ...ocess make sure the mote is in a vertical upright position and within range of the station 7 Repeat steps 4 6 for any additional motes to add 8 Press the Search button the magnifying glass on the RX30...

Page 18: ...t in the connection schedule Also note that the station will connect to HOBOlink when the device is powered up and when you press the Start button For RX3003 and RX3004 cellular models All connections...

Page 19: ...location Check the signal strength on the mote LCD on the location where you want to place the mote If there is only one or two bars on the signal strength indicator consider moving the mote to a loca...

Page 20: ...d for outdoor and weatherproof deployments and recommended for harsh indoor environments where debris could enter the station 1 Make sure all sensors and cables are installed including the solar panel...

Page 21: ...n or mote before opening it Check that all cables and wires are free of damage such as cracks cuts and splits Make sure cables and wires are still fastened securely and any conduit is still intact Ver...

Page 22: ...ranteed due to uncertainties in initial battery conditions and operating environment Use the following table as a guideline for estimating how long the station will run using a fully charged battery a...

Page 23: ...e separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV t...

Page 24: ...minutes in air moving 1 m sec with protective cap Operating Temperature Range 40 C to 75 C 40 F to 167 F Environmental Rating Weatherproof 0 to 100 RH intermittent condensing environments For best re...

Page 25: ...mounted properly the housing is weatherproof but not waterproof Refer to the station manual and Tripod Setup Guide for more information regarding setting up stations Connecting the Sensor to a Statio...

Page 26: ...erval See Measurement Operation for more information Operating Temperature Range 40 to 75 C 40 to 167 F Environmental Rating Sensor and Cable Jacket Weatherproof Housing Three cup polycarbonate anemom...

Page 27: ...place 5 Adjust the height of the sensor in the cross arm as necessary using one of the following methods and then tighten the nut and bolt until the cross arm just starts to deform a Loosen the tri cl...

Page 28: ...ogging at a 1 second interval the sensor will report the same wind speed its calculated average for three samples before calculating and reporting a new value for another three samples Gust speed is t...

Page 29: ...rproof Service Life 4 to 6 years typical depending upon environmental conditions Housing Injection molded plastic housing and vane static dissipating base lead free silicon bronze nose and aluminum mo...

Page 30: ...until snug 2 Insert the sensor mounting rod into the cross arm allowing the mounting rod to protrude 1 3 cm 1 2 inch from the bottom of the cross arm 3 Tighten the nut and bolt until the rod is sligh...

Page 31: ...urself so that the station is that number of degrees to the west of magnetic north 4 While viewing the sensor through binoculars instruct another person to rotate the sensor mounting rod to point the...

Page 32: ...logging at a 1 second interval the sensor will report the same wind direction its calculated average for three samples before calculating and reporting a new value for another three samples Measuremen...

Page 33: ...clamp unlimited with screws Compatible Sensors S THB 00x S TMB M0xx TMCx HB TMCx HD and external sensors from U23 00x or MX230x Maximum Sensor Diameter 1 22 cm 0 48 inches Mount temperature or temp R...

Reviews: