Onset HOBO RX3000 Series Manual Download Page 4

 

HOBO RX3000 Remote Monitoring Station Manual 

 

Device Components and Operation 

 

 

 

Station Door: 

This is the protective, hinged door covering the 

LCD and electronics. The station serial number and device key 
needed for HOBOlink registration are located on the inside of 
the door.

 

LCD Screen: 

This shows details about system, module, and 

sensor operation (see 

LCD Operation

). 

Select Button:

 Use this button to cycle through information 

about the smart sensors and optional modules (see 

LCD 

Operation

). 

Start/Stop Button

: Use this button to start and stop logging or 

clear a fault code (see 

LCD Operation

). 

Connect/Search Button:

 Use this button to connect to 

HOBOlink or search for new smart sensors (see 

LCD Operation)

Antenna: 

This is the external radio antenna for cellular 

communication in the RX3003 model. The RX3002 and RX3004 
models use an internal antenna.

 

SIM Card/Micro SIM Card: 

A SIM card is installed in the RX3003 

model or a micro SIM card is installed in the RX3004 model to 
enable cellular communications.

 

Grounding Wire Port:

 Use this port to connect a grounding wire 

(see 

Deploying and Mounting the Station

).

 

Module Slots:

 These are two slots for installing optional analog 

sensor, relay, or RXW Manager modules (see 

Setting up the 

Station

). 

Battery Port:

 Use this port to plug in the internal battery cable 

(see 

Setting up the Station 

and 

Battery Information

). 

Charging Port:

 Use this port to plug in an AC adapter, solar 

panel, or external power source to keep the battery charged 
(see 

Setting up the Station

 and 

Battery Information

). 

USB Port:

 Use this port to connect the station to the computer 

via USB cable as needed for HOBOware. 

Ethernet Connector:

 Use this port to connect an Ethernet RJ45 

cable for the RX3001 model (see 

Setting up the Station

). 

Smart Sensor Connectors:

 Use these input jacks to connect up 

to 10 smart sensors (see 

Setting up the Station

). The station can 

support up to 15 smart sensor data channels; some smart 
sensors have more than one data channel. 

Cable Access Openings:

 These are the two openings for 

connecting cables and wires to the station (see 

Setting up the 

Station

). Install the cover plates and rubber cable channels in 

these openings to create a weatherproof seal (see 

Deploying 

and Mounting the Station

). 

Vent.

 This vent allows pressure to equalize inside the station 

while keeping water out. Note that the pressure inside the 
station does not match the outside air pressure exactly. 
Therefore, a barometric pressure sensor deployed within the 
case cannot measure the true atmospheric pressure unless it 
has its own unrestricted vent to the outside. 

 

 

Battery Port 

Smart Sensor 
Connectors 

Cable Access Openings 

Vent 

SIM Card 
(RX3003) or 
Micro SIM Card 
(RX3004) 

LCD Screen  

Ethernet 

Connector 

(RX3001) 

Charging Port 

USB Port 

Module Slots 

Station Door 

Antenna 
(RX3003) 

Grounding 
Wire Port 

Connect/ 
Search 
Button 

Start/ 
Stop 
Button 

Select 
Button 

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for HOBO RX3000 Series

Page 1: ...ns AC power adapter AC U30 solar panel SOLAR xW or external power source 5 V DC to 17 V DC with external DC power cable CABLE RX PWR Rechargeable Battery Service Life Typical 3 5 years when operated i...

Page 2: ...dBm for 1 0 Mbps Cellular RX3003 and RX3004 Wireless Radio RX3003 GSM GPRS EDGE Quad band 850 900 1800 1900 MHz UMTS HSPA Five band 800 850 900 1900 2100 MHz RX3004 GSM GPRS EDGE Quad band 850 900 180...

Page 3: ...s product as complying with all relevant directives in the European Union EU RXMOD RXW 922 See last page Table of Contents Device Components and Operation 4 LCD Operation 5 Setting up the Station 7 a...

Page 4: ...ation Charging Port Use this port to plug in an AC adapter solar panel or external power source to keep the battery charged see Setting up the Station and Battery Information USB Port Use this port to...

Page 5: ...dicates the last connection to HOBOlink was ok indicates there was a problem with the last connection check the Connections log in HOBOlink Smart Sensor and Module Status This part of the LCD shows th...

Page 6: ...losed c In this example the first and third relays are open and the second one is closed This will blink in the lower right part of the LCD when a firmware update is underway It will display which mod...

Page 7: ...er module on the left and the relay module on the right for easier cable routing c Using a Phillips head screwdriver tighten the screw at the bottom of each module In this example an analog module is...

Page 8: ...eckbox f Enter the IP Address Subnet Mask Gateway and DNS Server Consult your Network Administrator for the appropriate addresses to complete these fields g Click Save in the RX3000 Manager Click Done...

Page 9: ...or one smart sensor through the larger of the two cable openings and plug it into one of the 10 smart sensor connectors Repeat for any additional smart sensors b Press the Select button to view the sm...

Page 10: ...ion 4 GND EX RTN 4 GND EX RTN 5 CH2 SIGNAL 5 CH4 SIGNAL 6 CH2 GND 6 CH4 GND 7 SHIELD 7 SHIELD Note All four input channels share the same common ground Analog Module Functional Diagram To connect rela...

Page 11: ...section on your station s page in HOBOlink c Click Save or click Next Smart Sensors Logging and Configuration You can configure both the global settings that affect all smart sensors logging interval...

Page 12: ...he sensor measurement type for that mote g Click one of the mote measurement types from menu under Module Wireless Sensors Logging as shown in the following example h Type a label for the measurement...

Page 13: ...he four analog sensor channels from the menu such as Channel 1 shown in this example g Select Enable Graph if you want the sensor data to be graphed in HOBOlink h Select Enable this channel if you wan...

Page 14: ...ired 4 Under Select Data to Export choose the name of the custom data export you want to be delivered or follow the previous set of steps to set up a custom data export 5 Under Data Destination select...

Page 15: ...ps send an email or text or close open or pulse one of the three relays if a relay module is installed For email or text enter the details and then select Send on Clear Also if you want an email or te...

Page 16: ...is inserted through the bottom of the station case Do not reconnect the power on the station until the mote is plugged in as shown 7 Plug in the battery and charging device and wait for the device to...

Page 17: ...ocess make sure the mote is in a vertical upright position and within range of the station 7 Repeat steps 4 6 for any additional motes to add 8 Press the Search button the magnifying glass on the RX30...

Page 18: ...t in the connection schedule Also note that the station will connect to HOBOlink when the device is powered up and when you press the Start button For RX3003 and RX3004 cellular models All connections...

Page 19: ...location Check the signal strength on the mote LCD on the location where you want to place the mote If there is only one or two bars on the signal strength indicator consider moving the mote to a loca...

Page 20: ...d for outdoor and weatherproof deployments and recommended for harsh indoor environments where debris could enter the station 1 Make sure all sensors and cables are installed including the solar panel...

Page 21: ...n or mote before opening it Check that all cables and wires are free of damage such as cracks cuts and splits Make sure cables and wires are still fastened securely and any conduit is still intact Ver...

Page 22: ...ranteed due to uncertainties in initial battery conditions and operating environment Use the following table as a guideline for estimating how long the station will run using a fully charged battery a...

Page 23: ...e separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV t...

Page 24: ...minutes in air moving 1 m sec with protective cap Operating Temperature Range 40 C to 75 C 40 F to 167 F Environmental Rating Weatherproof 0 to 100 RH intermittent condensing environments For best re...

Page 25: ...mounted properly the housing is weatherproof but not waterproof Refer to the station manual and Tripod Setup Guide for more information regarding setting up stations Connecting the Sensor to a Statio...

Page 26: ...erval See Measurement Operation for more information Operating Temperature Range 40 to 75 C 40 to 167 F Environmental Rating Sensor and Cable Jacket Weatherproof Housing Three cup polycarbonate anemom...

Page 27: ...place 5 Adjust the height of the sensor in the cross arm as necessary using one of the following methods and then tighten the nut and bolt until the cross arm just starts to deform a Loosen the tri cl...

Page 28: ...ogging at a 1 second interval the sensor will report the same wind speed its calculated average for three samples before calculating and reporting a new value for another three samples Gust speed is t...

Page 29: ...rproof Service Life 4 to 6 years typical depending upon environmental conditions Housing Injection molded plastic housing and vane static dissipating base lead free silicon bronze nose and aluminum mo...

Page 30: ...until snug 2 Insert the sensor mounting rod into the cross arm allowing the mounting rod to protrude 1 3 cm 1 2 inch from the bottom of the cross arm 3 Tighten the nut and bolt until the rod is sligh...

Page 31: ...urself so that the station is that number of degrees to the west of magnetic north 4 While viewing the sensor through binoculars instruct another person to rotate the sensor mounting rod to point the...

Page 32: ...logging at a 1 second interval the sensor will report the same wind direction its calculated average for three samples before calculating and reporting a new value for another three samples Measuremen...

Page 33: ...clamp unlimited with screws Compatible Sensors S THB 00x S TMB M0xx TMCx HB TMCx HD and external sensors from U23 00x or MX230x Maximum Sensor Diameter 1 22 cm 0 48 inches Mount temperature or temp R...

Reviews: