RXW Leaf Wetness Sensor (RXW-LWA-xxx) Manual 

1-800-LOGGERS 

www.onsetcomp.com 

last through the night and cloudy periods. Make sure the mote 

is placed in a location that will receive several hours of sunlight 

each day. If the mote does not receive enough sunlight to 

recharge the batteries, the battery life is estimated at 3–4 

months. When batteries are regularly recharged, expected 

battery life is estimated at 3–5 years. Battery life varies based 

on the ambient temperature where the mote is deployed, the 

logging interval, the number of tripped alarms, and other 

factors. Deployments in extremely cold or hot temperatures 

can impact battery life. Estimates are not guaranteed due to 

uncertainties in initial battery conditions and operating 

environment. 
Mote operation will stop when battery voltage drops to 1.8 V. 

Mote operation will return if the battery recharges to 2.3 V. If 

the batteries are unable to be recharged, replace them with 

fresh rechargeable batteries. 

Note:

 if you install used 

rechargeable batteries that together are less than 2.3 V, the 

mote will not resume operation. 
To replace rechargeable batteries: 
1.

 

Open the mote door. 

2.

 

Remove the old batteries and install fresh ones observing 

polarity. 

3.

 

Make sure the solar panel cable is plugged in. 

 

The mote contacts the network once the new batteries are 

installed. The green LED blinks during this process while the 

bars in the signal strength indicator on the LCD cycle from left 

to right and then the x icon blinks. Once this process is 

complete, the x icon is removed, the green LED stops blinking, 

and the blue LED begins blinking instead. 

Lithium Batteries 

You can use two 1.5 V lithium batteries (HWSB-LI) for operation 

at the extreme ends of the mote operating range. Lithium 

battery life is an estimated at 1 year, but varies based on the 

ambient temperature where the mote is deployed, the logging 

interval, the number of tripped alarms, and other factors. 

Estimates are not guaranteed due to uncertainties in initial 

battery conditions and operating environment. When using 

lithium batteries, you must disconnect the solar panel cable 

because the batteries will not be recharged. 
To install lithium batteries: 
1.

 

Open the mote door. 

2.

 

Remove any old batteries and install the new ones 

observing polarity. 

3.

 

Push in the side tab of the solar panel cable connector and 

pull the connector out of the cable port. 

4.

 

Place the connector in the slot on the inside of the mote 

door. Make sure the solar panel cables are tucked inside the 

door so that they do not interfere with the interior seal 

when the mote is closed. 

 

The mote contacts the network once the new batteries are 

installed. The green LED blinks quickly while the mote searches 

for a network to join and then blinks slowly while it completes 

the network registration. Once the mote has finished joining 

the network, the green LED turns off and the blue LED then 

blinks indefinitely while the mote is part of the network. 

 

WARNING:

 Do not cut open, incinerate, heat above 85°C 

(185°F), or recharge the lithium batteries. The batteries may 

explode if the mote is exposed to extreme heat or conditions 

that could damage or destroy the battery cases. Do not mix 

battery types, either by chemistry or age; batteries may rupture 

or explode. Do not dispose of the logger or batteries in fire. Do 

not expose the contents of the batteries to water. Dispose of 

the batteries according to local regulations for lithium 

batteries.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Store the solar 

panel connector 

here when using 

lithium batteries 

Make sure 

solar panel 

cable is 

installed 

when using 

rechargeable 

batteries 

Summary of Contents for HOBO HOBOnet RXW Series

Page 1: ...1 MHz RXW LWA 922 916 924 MHz Modulation Employed OQPSK Offset Quadrature Phase Shift Keying Data Rate Up to 250 kbps non adjustable Duty Cycle 1 Maximum Number of Motes 50 motes per one RX Wireless S...

Page 2: ...h Use the two latches to open and close the mote door Ground Wire Port Use this port to connect a ground wire see Deploying and Mounting Antenna This is the built in antenna for the radio communicatio...

Page 3: ...AN QSG RX3000 for RX3000 stations To add a mote to the network 1 If the LCD is blank on the station press any button to wake it up 2 Press the Select button once which shows the number of smart sensor...

Page 4: ...e distance and signal strength Place the mote so there is full line of sight with the next mote If there is an obstruction between two sensor motes or between the sensor mote and the manager then use...

Page 5: ...sor will retain moisture and that will ultimately affect the sensor s performance You should periodically inspect the sensor and gently clean the sensor grid once per year with a non abrasive rag mild...

Page 6: ...n at the extreme ends of the mote operating range Lithium battery life is an estimated at 1 year but varies based on the ambient temperature where the mote is deployed the logging interval the number...

Page 7: ...e undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Industry Canada...

Reviews: