Stereo Streaming Gain Distribution

Figure 10. Memory Select A Utilities Tab

When HRX is disabled on Ayre SA3291 device, the gain

on the front-end of the system can be adjusted using the
HRXPreGain and HRXPostAtten parameters
(see Figure 10) in combination with the Wideband Gain
parameter to get the desired gain distribution.

Please note that HRXPreGain and HRXPostAtten are

provided to give control over the preamplifier gain settings
when HRX is enabled. Normally the default values should
be used.

Ayre SA3291 Wireless System Consideration

With the configuration of the wireless parameters

properly set, the devices will perform as expected under
normal operating circumstances.

However, because these devices are based on wireless

technology, there are certain situations where the behavior
of the devices needs to be anticipated.

Streaming Reception

Streaming audio will continue to be received when the

user changes memory selects, unless the MS selected does
not have wireless streaming enabled.

Streaming audio will be received until the hearing aid

detects that wireless audio has been missing for the length
of its timeout value “LowPowerDelay”.

If the hearing aid goes out of range of the relay device but

comes back into range before the timeout has expired, it will
reconnect and resume audio output.

If the hearing aid is turned off while streaming and turned

back on, it will not resume streaming until it receives another
wireless command to initiate streaming. (This will need to
be initiated by the relay device.)

If a relay device is transmitting while binaural telecoil is

enabled, it will disrupt the ear-to-ear audio streaming. This
cannot be prevented by the hearing aid, so the relay device
and hearing aid user must manage this scenario.

Remote Control

Ayre SA3291 can receive wireless remote-control

messages from a remote control device.

Remote control functions are supported in all operating

modes with the exception of binaural telecoil modes, where
MS changes are ignored. This is to prevent a streaming audio
source from interrupting a telephone conversation.

The hearing aids will be paired with a remote control at the

time of manufacturing or fitting.

It is possible to wirelessly pair the hearing aid with a new

remote control in the event that the original device is lost or
destroyed.

Summary of Contents for Ayre SA3291

Page 1: ...f any support or applications information provided by onsemi Typical parameters which may be provided in onsemi data sheets and or specifications can and do vary in different applications and actual p...

Page 2: ...distinguish which device should be allowed to receive a particular signal The address consists of a Vendor ID Network ID and a Device ID each of which can be programmed using IDS There are two basic m...

Page 3: ...in the following tabs of the IDS user interface Setting tab Main wireless parameter settings Memory specific tabs Front end tab Wireless front end mode settings specifically binaural telecoil and mic...

Page 4: ...lable corresponding to a range of 0 to 1 ms in 0 625 mS increments For a sampling frequency of 32 kHz a value of 0 to 32 is available corresponding to a range of 0 to 1 ms in 0 313 mS increments TxLev...

Page 5: ...mmable low power delay setting see section Setting Tab Wireless Parameters LowPowerDelay the hearing aid will return to the previous non wireless memory NOTE Streaming by a remote control will disrupt...

Page 6: ...s memory NOTE Streaming by a remote control will disrupt the mic plus binaural telecoil audio link until the streaming ceases For this reason IDS will restrict users from enabling wireless streaming w...

Page 7: ...less streaming signal when the streaming signal is a Stereo Audio source such as a MP3 player StereoMWAtten Adjusts the attenuation of the local microphone from 0 dB to 24 dB and off when the streamin...

Page 8: ...e hearing aid detects that wireless audio has been missing for the length of its timeout value LowPowerDelay If the hearing aid goes out of range of the relay device but comes back into range before t...

Page 9: ...ny other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur Should Buyer purchase or use SCILLC products for any such unintended o...

Reviews: