Digital Tachometer (For high speed)
HR-6800
Electromagnetic Detector
MP-5350
(The sensor is not included in a price of HR-6800)
Instruction Manual (Basic Operations)
Thank you for your selection of the HR-6800 Digital Ta-
chometer.
To ensure the performance of the HR-6800, please read
this manual thoroughly.
Warnings and Cautions
In this document precautions are classified into two cat-
egories: WARNING and CAUTION. This depends on the
degree of danger or damage possible if the precaution
is ignored and the product is used incorrectly.
1
Power switch
Turns the power ON or OFF.
2
Display
Displays the measurement value and various settings.
3
Input connector
Connected with the Detector with the supplied connection
cable.
4
RECALL &
↑
switch
Used for memory call during measurement and numeri-
cal input in the parameter setup mode.
5
MENU switch
Used to switch between the measurement mode and the
parameter setup mode.
The lock mode can be set and canceled by pressing this
switch for 3 seconds or longer.
6
MEMORY &
→
switch
Used for memory writing during measurement and nu-
merical digit shift in the parameter setup mode.
7
MODE & NEXT switch
Used for mode change during measurement and item
selection in the parameter setup mode.
8
Indicator (input signal indicator)
When the detector circuit detects a rotational signal, the
LED indicator lights up.
9
Type A/B selector switch
Used to select Type A or B.
0
Trigger level adjustment volume
Volume for adjusting the trigger level.
q
Tripod mounting hole
Used to mount a tripod.
w
Battery cover
e
Connector cover
Cover for the power inlet and output connectors.
r
DC power input
Input terminal for connecting the dedicated AC adapter.
(when the dedicated AC adapter and dry batteries are
used together, the AC adapter is given priority.)
t
Analog output
Terminal for connection with a recorder, etc. through
the optional AX-501 cord.
y
Pulse output
Terminal for connection with an FFT analyzer, etc.
through the optional AX-501 cord.
u
CONDITION display
Displays the measurement mode, LOW battery, and
errors.
i
MAIN display
Displays measurement values, selections, settings, etc.
o
SUB display
Displays memory addresses, settings, etc.
p
UNIT display
Multiplies the measured value in the MAIN display by
ten for readout in "r/min."
a
Detecting element
Bring the detecting element at the end of the Detector
close to the body of revolution under measurement.
s
Output connector
Connected with the HR-6800 unit using the supplied
connection cable.
1.Overview
The HR-6800 Digital Tachometer is a handy tachometer with
built-in batteries integrating the measurement unit and dis-
play unit. It is designed for measurement of bodies of revolu-
tion for dental instruments, textile machines, and general-
purpose high-speed machine tools, etc.
With the use a dedicated Detector, the HR-6800 makes it
possible to measure the rotational speed of the body of revo-
lution under measurement.
Up to 20 measurement data items can be stored in the HR-
6800 unit using the memory function, which is useful for sub-
sequent confirmation.
The display unit displays the rotational speed (x10 r/min) with
a 5-digit number.
The equipment is provided with an analog output (inter-
changeable with a monitor output) and a pulse output. The
analog output is used for recording with a data recorder, etc.,
and the pulse output for tracking analysis with an FFT ana-
lyzer.
2.Features
・
Measurement from low to high rotational speeds (100 to
999,990 r/min)
・
High sensitivity
・
MAX and MIN modes for displaying the maximum and
minimum values
・
Convenient memory function (up to 20 items can be
memorized) for confirmation of measurement results
・
Over mark function for indicating measurement values
exceeding a specified value
・
Analog output, sensor signal monitor output, and pulse
output
・
Type AAA batteries and AC adapter commonly used
・
Back light function which is convenient for use in dark
places
3.Measurement Principle
The Detector incorporates a permanent magnet and a de-
tection coil to detect the rotational speed of an object under
measurement based on the principle of electromagnetic in-
duction.
4.Unpacking
When you unpack the unit, make sure that you have all the
following:
【
HR-6800
】
①
HR-6800 main unit .................................................. x1
②
Type AAA alkaline dry battery ................................ x4
③
Instruction manual ................ x2 (2 different manuals)
④
Carrying case ......................................................... x1
⑤
MI-0301 Tripod attachment adapter ........................ x1
【
MP-5350
】
(The sensor is not included in a price of HR-6800)
①
Detector (MP-5350) ................................................ x1
②
Connection cable (1m) ........................................... x1
Overview
o
i
u
p
6
7
4
2
1
8
3
e
5
ANALOG
PULSE
6 V
0.5 A
r t y
q
w
180.5
66
14
47.5
TRIG LEVEL
Type
A B
9
0
189.5
107
13
a
s
1
HR-6800 main unit
②
Type AAA
alkaline dry batteries
3
Instruction manuals
4
Carrying case
Hig
h-spe
ed T
ach
om
ete
r
HR-6800
Instruction Manual (Function Reference)
Cop
yright © ONO SOKKI CO
.,L
TD
.
2005 All r
ights reser
ved.
Than
k you
for y
our s
electi
on o
f th
e H
R-6
800 H
igh-
spee
d Tach
omet
er.
To e
nsure
the p
erform
ance o
f th
e H
R-6
800, p
lease
read
this m
anua
l th
orou
ghly.
Hig
h-sp
eed
Tac
hom
ete
r
HR-6800
Electrom
agn
etic
Dete
cto
r
MP-5350
Instruction Manual (Basic Operations)
Cop
yright © ONO SOKKI CO
.,L
TD
.
2005 All r
ights reser
ved.
Than
k you
for y
our se
lectio
n of th
e H
R-6
800 H
igh-
speed
Tach
omete
r.
To e
nsure th
e perfo
rman
ce o
f th
e H
R-6
800, p
lease
read
this m
anua
l th
orou
ghly
.
⑤
Tripod attachment adapter (MI-0301)
Name and Function of Each Section
Observe the Following Points before Use
CAUTION
●
Do not drop the equipment or apply excessive shock to
it.
Since this equipment incorporates high-precision elec-
tronic parts, be careful not to drop it or apply strong shock.
●
Wipe dirt off using a dry cloth or a cloth dampened with
neutral detergent and squeezed firmly. Do not use vola-
tile oils (thinner or benzine) or alcohols.
●
Be sure to use the supplied connection cables.
Using cables other than the supplied one may make it
impossible to obtain specified performance or, in the worst
case, cause damage to the equipment.
●
Measurement in strong magnetic field or near an AC line
is not possible.
Since this equipment has a high input sensitivity to en-
able measurement with a minute signal, measurement in
strong magnetic field or near an AC line is not possible.
WARNING
●
Perform measurement using enough care with the target
under measurement rotating at high speeds.
Be careful not to allow connection cables to be caught by
rotating sections.
●
When using an AC adapter, be sure to use a dedicated
AC adapter (option).
Using adapters other than the optional one may cause
failure.
●
Avoid using the equipment in places subject to rapid tem-
perature change.
Do not move the equipment rapidly from a hot place to a
cold one or vice versa. Condensation can form inside the
unit which may cause failure.
●
Be careful not to get water, oil, dust, or foreign materials
inside the unit.
Do not use the equipment in places where you may get
water or oil or places which are humid or dusty.
1
MP-5350 Detector
②
Connection cable
Copyright
©
ONO SOKKI CO.,LTD.
2007 All rights reserved.
■
Omission of Issuance of Certificate
This product has been tested under strict inspections for
correct operation before shipment. Please note that the
issuance of certificate is omitted.
■
Warranty
1. This product is covered by a warranty for a period of one
year from the date of delivery.
2. This warranty covers free-of-charge repair during the
warranty period for defects occurred while the product is
used under correct operating conditions according to de-
scriptions in this manual and notices on the unit label.
3. For free-of-charge repair during the warranty period, con-
tact your dealer or your nearest Ono Sokki sales office
nearby.
4. Even during the warranty period, the following failures
will be handled on a fee basis.
(a) Failures or damages occurring through misuse,
misoperation, repairing without ONO SOKKI’S ap-
proval.
(b) Failures or damages occurring through mishandling
(dropping) during transportation after purchase.
(c) Failures or damages occurring by an Act of God (fires,
earthquakes, flooding, and lightening), environmen-
tal disruption, or abnormal voltage.
(d) Replenishment of expendable supplies, spare parts,
and accessories.
WARNING
CAUTION
This symbol is used to indicate precautions
where there is a risk of death or serious
personal injury to the operator if the product is
handled incorrectly.
This symbol is used to indicate precautions
where there is a risk of some personal injury
to the operator or only material damage to the
product if the product is handled incorrectly.
This guarantee covers only the performance of the product itself only.
All inconvenience by the trouble of this product is not included.
*Outer appearance and specifications are subject to change without prior notice.
HOME PAGE: http://www.onosokki.co.jp/English/english.htm
WORLDWIDE
ONO SOKKI CO., LTD.
1-16-1 Hakusan, Midori-ku,
Yokohama 226-8507, Japan
Phone : 045-935-3976
Fax
: 045-930-1906
E-mail : [email protected]
B00002033 / IM07062203(2) 0
81
(MS)020