background image

1.Power Supply

The HR-6800 operates on four Type AAA batteries or the

dedicated AC adapter (option: PB-7080).

If the batteries are consumed and the LOW mark "

"

appears, replace them with new ones. Be sure to replace

all the four batteries at the same time.

Battery replacement procedure

While pushing lightly the two (anti-slip) slots of the

battery cover with your finger, slide it to remove.

Put the batteries properly in the battery compartment

with the correct polarity (+/-).

Put the battery cover.

2.MI-0301 Tripod Attachment Adapter

With the use of the supplied tripod attachment adapter,

the Detector can be installed using a commercially avail-

able tripod.

Attach the Detector to and detach it from the tripod attach-

ment adapter as shown below.

1.Measurement Section

Objects under measurement: Bodies of revolution for dental in-

struments

Bodies of revolution for textile ma-

chines

Bodies of revolution for high-speed

machine tools, etc.

* The object under measurement needs

to be polarized.

Operation method

: Periodic operation method

Measuring time

: 50 ms + Input signal 10-period time

or less

Input frequency range

: 1.6 Hz to 16.666 kHz

Measuring unit

: 10 r/min (rotational speed)

Measuring range

: 100 to 999990 r/min (selectable)

Measurement accuracy : Display value x (

±

0.02 %) 

±

1 count

Over range function

: If the measurement value exceeds the

display range, over range "

"

appears.

Upper limit rotation warning function: If the rotational speed ex-

ceeds a preset upper limit, upper limit

warning "

" appears.

Trigger adjustment function: Can be adjusted using the rotary

volume on the right-hand side face of

the HR-6800 unit.

2.Detecting Element

           

(The sensor is not included in a price of HR-6800)

Detection method

: Electromagnetic induction

DC resistance

: 25 to 40 

 [20 ˚C]

Operating temperature range: 0 ˚C to +40 ˚C

Storage temperature range: -10 ˚C to +50 ˚C

Resistance to vibration : 19.6 m/s

2

Resistance to shock

: 490 m/s

2

Mass

: About 50 g (detecting element only)

Dimensions

: 107 x ø14 mm

3.Display Section

Number of display digits : 5 digits

Character height

: 10.2 mm

Indicator

: 7-segment LCD with back light

Refresh time

: About 1 s/0.5 s selectable

4.Measurement Mode

MAX (peak hold) : Displays the maximum value during mea-

surement.

MIN (peak hold)

: Displays the minimum value during mea-

surement.

Others

: Displays the current measurement value.

Memory function : Up to 20 measurement values can be

memorized each time the memory switch is

pressed. Since these values are stored in

non-volatile memory, they are retained even

after the power is turned OFF.

Specifications

5.Analog Output Section

REVO

Output contents

: Output to the display value of rotational

speed.

Voltage range

: 0 to F.S./0 to 1 V

(The full scale can be set with a setup

parameter.)

Conversion method : 10-bit D/A conversion method

Linearity

:

±

1 % of F.S.

Output refresh time : 50 ms + Input signal 10-period time or

less

Temperature stability :

±

0.05 % of F.S./˚C (ZERO & SPAN)

Setup error

:

±

0.5 % of F.S. (adjustment setup error

at the time of shipment, ZERO & SPAN)

Load resistance

: 100 k

 or more

Output connector

: Super mini jack (ø2.5)

SIG

Output contents

: Analog output for monitoring after wave-

form shaping of the sensor signal (be-

fore pulse waveform conversion)

Load resistance

: 100 k

 or more

Output connector

: Super mini jack (ø2.5/Commonly used

with REVO output)

6.Pulse Output Section

Output timing

: Outputs one pulse for each signal de-

tection.

(For bodies of revolution with one out-

put per rotation, outputs one pulse per

rotation.)

Output voltage

: Hi level=4.5 V or higher

Lo level=0.5 V or lower

Output logic

: Positive logic pulse

Load resistance

: 100 k

 or more

Output connector

: Super mini jack (ø2.5)

7.General Specifications

Power supply

: Type AAA dry battery (x4) or dedi-

cated AC adapter (PB-7080)

Continuous operating time: About 13 hours (back light OFF)

About 8 hours (back light ON)

(When alkaline batteries are used at

20 ˚C)

Battery LOW display

: Lights up at about 4.5 V.

Operating temperature range: 0 ˚C to +40 ˚C

Storage temperature range: -10 ˚C to +50 ˚C

Operating humidity range: +35 to +85 %RH (without conden-

sation)

Storage humidity range : +35 to +85 %RH (without conden-

sation)

Mass

: About 230 g (HR-6800 unit only, bat-

teries not included)

Dimensions

: 189.5 x 66.0 x 47.5 mm (HR-6800

unit)

Before Use

Battery polarity display

4.Measurement

Connect the HR-6800 unit with the Detector using the

supplied cable.

Select Type A or B using the Type selector switch on the

side face.

Slide the power switch to turn the power ON.

Set the number of pulses per rotation (P/R) and other

parameters according to the object under measurement.

Bring the Detector close to the object under measurement.

Bring the end or its side face of the Detector to the body

of revolution as shown below.

Detection at the end

Detection at side face of the end

During measurement, turn the trigger level adjustment

volume so that the indicator blinks stably and the rotational

speed be displayed. Since the center value of the trigger

level adjustment volume is 5, gradually increase or

decrease the trigger level from 5 to adjust the trigger level.

Perform measurement.

TRIG LEVEL

5

Options

Storage

The storage temperature range of the HR-6800 is -10˚C

to +50˚C. When you store it, avoid locations where the

temperature is extremely high or low or the humidity is

high. Store it in a place which is well-ventilated and not

exposed to direct sunlight. If you do not use it for a pro-

longed period of time, be sure to remove the batteries to

prevent accident caused by battery leakage, etc.

AX-501: Output cord

PB-7080: AC adapter

(IN: 100 to 120 VAC, OUT: 6 VDC)

Body of revolution 
under measurement

5

20 mm

3.Measurable Bodies of Revolution

The HR-6800 enables measurement of the following bodies

of revolution:

A body of revolution with a magnet embedded

Most stabilized measurement is possible.

This system is recommended for a drill for rotation test.

A body of revolution partially polarized

A magnet is rubbed on a part of the body of revolution for

polarization before measurement. If the magnetic force

weakens with time, polarization is performed again.

A body of revolution with a bumpy shape

Since a magnet is embedded in the Detector of the HR-

6800, whether a body of revolution can be measured

depends on its shape. However, depending on the material

and shape of the body of revolution, a detected signal may

become minute making detection of rotation difficult.

Therefore, if possible, magnet-based detection is

recommended.

Note: Since the Detector has frequency characteristics,

it needs strong magnetic force particularly when

measuring low rotational speed.

Refer to the following rough standard of magnetic

force:

100 r/min: 10 mT or more

10000 r/min: 5 mT or more

100000 r/min: 1 mT or more

Note: Measurement is not possible in places where

strong magnetic field is present around the mea-

suring point.

RANGE

Hi

Lo

Type selection

 

A

B

10,000 to 999,990 r/min

100 to   50,000 r/min

200,000 to 999,990 r/min

Rotational speed range

* When the number of pulses is set to "1"

* Generally, use Type A.

Attachment

Detachment

10

5

20 mm

Applicable Standards

CE Marking

EN61326

EN61010-1

: This mark declares the compliance with

EC instructions.