background image

22

Installation and Preparation

2.5  Preparation for Power Supply (AC Adapter 

Connection)

!

WARNING

• 

Always use the AC adapter within the specified range of rated voltage. 

 

The supply voltage of the AC adapter that comes with the CF-4700 FFT comparator is 100 to 240 VAC (50/60 Hz). Note that 
using a power supply other than specified could cause a fire or electric shock.

•  Always use the AC adapter and power cable that come with the CF-4700 FFT comparator. Note that using ones other than 

supplied could cause a fire or electric shock.

Connect the AC adapter that comes with the product as follows:

[1]

  Check the connections of peripheral devices.

Make sure that the relevant peripheral devices are correctly connected to the CF-4700 FFT comparator. For 
details, refer to the instruction manuals of the peripheral equipment connected.

[2]

  Connect the AC adapter.

Insert the plug of the AC adapter securely into the bottom of the DC power input terminal (DC IN) located on the 
rear panel of the CF-4700 FFT comparator.

[3]

  Connect the AC power cable to the AC adapter.

Fully insert the AC power cable into the AC adapter.
Next, insert the power plug of the AC power cable into the 3-wire AC outlet (100 to 240 VAC).

DC IN

AC adapter

AC power cable

100 VAC to 240 VAC 

50/60 Hz

Summary of Contents for CF-4700

Page 1: ...User guide CF 4700 FFT Comparator...

Page 2: ......

Page 3: ...riation of a specific degree while varying the revolution speed The installed optional CF 0473 amplitude modulation component extraction function bandpass envelop monitoring function enables checking...

Page 4: ...efforts to restore this product the program of the software or any data Likewise Ono Sokki will not be held responsible for the product and the program of the software that is stored and used in prod...

Page 5: ...is reference guide describes basic operating procedures for the following Preparation of CF 4700 and measurement FFT analysis CF 0471 tracking function Comparator block shape function The reference gu...

Page 6: ...al injury but can damage your property including the system facilities or equipment z z Meanings of symbols Precautions and notices for danger are given by three different symbols Attention Prohibitio...

Page 7: ...Precautions on disposal CAUTION When disposing the CF 4700 FFT comparator or its accessories be sure to observe relevant local laws and regulations For details please contact your local municipalitie...

Page 8: ...78 power source backup function Using a battery pack other than the specified one may result in explosions causing an extremely hazardous situation When disposing of a battery pack be sure to observe...

Page 9: ...5 CD ROM 1 Stores reference manuals utilities DLLs 6 Hardware User s Guide this document 1 The reference manual is stored as a Help file in PDF in the CD ROM 7 Ferrite core 1 For signal input contact...

Page 10: ...des and Top 17 2 Installation and Preparation 18 2 1 Workflow from Installation to Measurement 18 2 2 Installation 19 2 3 System Configuration Examples 20 2 4 Connection of Measuring Equipment 21 2 5...

Page 11: ...Connectors Type A 35 4 2 Connection to Mass Storage Connector 37 4 3 SD Card Handling 40 4 4 Media Formatting Procedure 42 4 5 Memory Management Directory and File Naming Rules 43 5 Optional Hardware...

Page 12: ...type touch panel POWER switch AC adapter connection terminal Interface terminal Signal input terminal Comparator contact terminal Battery pack housing plate used when the optional CF 0478 power sourc...

Page 13: ...s equipped with a resistive touch panel The touch panel of CF 4700 FFT comparator employs a human interface that enables the software to be operated with finger tips see the figure below instead of us...

Page 14: ...green The CF 4700 FFT comparator then starts to boot Release the finger from the POWER switch after the device beeps and the POWER indicator is lit green OFF Press the POWER switch for more than 1 sec...

Page 15: ...ction is added a USB mass storage corresponding to a mass storage class can be connected and accordingly a personal computer PC can be connected Connecting the PC enables the data in the CF 4700 FFT c...

Page 16: ...nal 14 RS 232C terminal 15 Comparator output contact terminal 16 Status output contact terminal 17 Signal input contact terminal Battery housing plate used with the optional CF 0478 battery pack 8 EXT...

Page 17: ...pter that comes with the CF 4700 FFT comparator Using an AC adapter other than specified is very dangerous since it could cause not only a failure or malfunction but also a fire or electric shock 13 L...

Page 18: ...nment up to 9 terminals selection of panel conditions 4 terminals switching of decision blocks 4 terminals Input type Driven by contact or open collector common collective insulation Input current 5 m...

Page 19: ...Removing the handle could cause a malfunction or damage the device Never try to remove it If the handle needs to be removed contact the nearest Ono Sokki sales office or the distributor where you purc...

Page 20: ...on and secure the installation area for the CF 4700 comparator For connection of peripheral devices refer to Section 2 3 System Configuration Examples For connection of measuring sensors and equipment...

Page 21: ...cting it to a wrong destination could cause a fire due to a short circuit For the handling and connection of the interface cable observe the following precautions Do not use broken cables or cable con...

Page 22: ...ckup NP 3000 acceleration pickup TEDS LV series laser vibrometer LG 981 Rotary encoder TM 3100 series tachometer Wireless LAN adapter Personal computer Windows 7 Headphones STEREO NP 0021 CH 6130 6140...

Page 23: ...that is displayed after touching the following soft keys in the order mentioned Home Input and Input Cond For details refer to the Reference Guide included in the attached CD ROM z z Connection of th...

Page 24: ...ck Connect the AC adapter that comes with the product as follows 1 Check the connections of peripheral devices Make sure that the relevant peripheral devices are correctly connected to the CF 4700 FFT...

Page 25: ...hat if the POWER switch is kept pressed down even after the POWER indicator is lit green the CF 4700 FFT comparator is forcibly powered off and fails to start to boot Note that the power cannot be tur...

Page 26: ...Basic Operations 3 1 Main Screen CF 4700 Main Screen Mode Setting key area lower setting key functions Condition name Channel information Graph area Mode selection Setting key area upper setting keys...

Page 27: ...ystem setting External device setting Display switching button External trigger signal input indicator Trigger indicator Tool area Utility area System information area CAUTION This manual user s guide...

Page 28: ...FFT comparator input information such as signal input and level monitor is displayed in the input information area Mode Condition name Signal input channel Revolution indication Trigger External trigg...

Page 29: ...ual components refer to the Reference Guide PDF Help stored on the CD ROM that comes with the CF 4700 FFT comparator Display switching button The display switches to input information or communication...

Page 30: ...ion destination and connection environment If the connection is wrong correct it If an IP address beginning from 169 is still displayed even after confirming the correct connection environment reopen...

Page 31: ...F 0478 power source backup function is installed the following status indications are used to display the availability of battery pack and the state of charge If the power source backup function is no...

Page 32: ...he CF 4700 FFT comparator Tool area component names and functions The tool area has the buttons for switching between the status list and shortcut list in the utility area Touching the status list but...

Page 33: ...Trigger information Data memory information Schedule information z z Shortcut list Touching the shortcut list button displays the shortcut list in the utility area Frequently used commands and functi...

Page 34: ...Comparator key Delta pointer key Start key Stop key Save key Search cursor key Trigger key Average key Pause key Schedule key Frequency range switching key Spectrum waveform display key Time waveform...

Page 35: ...Registration cancel key Comparator registration key Start key Waveform display switching key Display of comparator registration No Comparator registration No key ascending Average key Schedule key Sto...

Page 36: ...raph number switching and graph type switching buttons and the soft key indicating the hierarchy The lower stage has the soft keys indicating functions For the functions and other details of individua...

Page 37: ...CF 4700 FFT comparator The USB flash memory thus installed can be specified as the storage destination of measurement analysis and condition data The data stored in the USB flash memory can also be r...

Page 38: ...h soft keys Home Memory and Data or Condition in this order to display the memory management screen Touch Location on the memory management screen and touch USB F in the menu that has been opened This...

Page 39: ...ifying them from the personal computer Mass storage connection USB port A type Personal computer Windows 7 USB mass storage cable CAUTION The personal computer to be connected by the USB mass storage...

Page 40: ...l computer and CF 4700 FFT comparator When the mass storage mode begins in the CF 4700 FFT comparator device driver software is automatically installed in the personal computer When the installation i...

Page 41: ...button on the Safely Remove Hardware icon on the task bar Then click Remove NetChip Firmware API Mass Storage in the menu that has popped up After confirming the message Remove Hardware disconnect th...

Page 42: ...t of the CF 4700 FFT comparator The SD card thus installed can be specified as the storage destination of measurement and analysis data or condition data The data stored in the SD card can also be loa...

Page 43: ...o pop up a menu and then touch SD Card Unmount Message Media has been unmounted appears Touch the OK button External device settings 2 Remove the SD card Press back all the way the SD card that has be...

Page 44: ...h memory as an example 1 Install the USB flash memory in the type A USB port of the CF 4700 FFT comparator In the case of an SD card unlock the SD card hold the card with the surface facing up and ins...

Page 45: ...700 dat bmp txt c4p trc dat bmp txt trc CF 4700 DataMem data folder 1 10 Panel Panel condition folder File naming rules z z Data file naming rules The following types of information are given as neede...

Page 46: ...plitude modulation component extraction function is added to the CF 4700 FFT comparator frequency bands of abnormal noise can be set through any filter while listening to the correlation with the sens...

Page 47: ...ttery pack other than specified could cause a smoke fire electric shock or explosion in addition to failures and malfunctions Do not heat or disassemble the battery pack short circuit it or throw it i...

Page 48: ...able the time until the Normal Operation indication is switched to the Unavailabe indication or is about one and half month with a brand new battery To turn off the power source while the status of th...

Page 49: ...ng the battery pack is limited due to the ambient temperature While charging with limitations use the POWER switch on the CF 4700 FFT comparator to turn off the power To use the backup function charge...

Page 50: ...ging battery with limitations Charge stopped Charging stopped No battery No battery pack installed No option CF 0478 option is not installed Show details Hide details You can expand to see the details...

Page 51: ...nstallation and secure it with the screws z z Checking the battery charge level The battery pack has the indicator lamp and the switch to show the charge level Pressing the charge level check switch t...

Page 52: ...tart after termination Ensure that power is kept supplied to the AC adapter POWER OFF ON POWER ON DC IN AC adapter AC power source cord 100 to 240 V AC 50 or 60 Hz z z Automatic power off When the pow...

Page 53: ...Vrms 31 62 Vrms 2 ranges DC offset 60 dB full scale or less auto zero ON at DC coupling Input level monitor Red LED lit in excessive input lit at 95 of full scale range Frequency range DC to 40 kHz A...

Page 54: ...or Waveform can be checked on the screen External trigger input display Screen display at the pulse detection EXT TRIG blinking Analog filter HPF standard Cut off frequency fixed 1 Hz 3 Hz 10 Hz The 1...

Page 55: ...ngular Hanning FlatTop Time axis waveform processing function 1st order 2nd order differential single double integration Absolute value conversion DC cancel trend removal smoothing FFT realtime rate 4...

Page 56: ...specified by the EU value By data type for block Invalidated if differentiated or integrated automatic deletion not implemented Block mode method Peak level Peak MAX maximum value InsideMax Partial o...

Page 57: ...r after each analysis Automatic data saving Automatic saving only in the case of NG or all measurement results can be saved Block or shape specification method Specifying an area by dragging on the sc...

Page 58: ...ON OFF Data Store Selection of Any Panel Condition 15 types Input format Contact or open collector driving Sink current 5 mA Negative logic Isolation 5 V Output STATUS OUTPUT Number of outputs 4 inde...

Page 59: ...val ground terminal External dimensions 220 mm W 185 mm H 220 mm D Not including the handle stand and other protruding parts Comparator cooling Natural air cooling fanless Mass With no options install...

Page 60: ...storage function Accessory USB mass storage cable 1 5 m 1 Optional Hardware CF 0473 Amplitude modulation component extraction function Accessory Ferrite core E04SR200932 1 CF 0478 Power Source Backup...

Page 61: ...can turn on or off the comparator power Battery Secondary lithium ion battery Installation Built in the comparator detachable Quantity One Battery status display Comparator screen With the secondary b...

Page 62: ...60 External Dimensions 7 External Dimensions...

Page 63: ......

Page 64: ......

Reviews: